English
Language : 

VMMK-2103_15 Datasheet, PDF (1/12 Pages) AVAGO TECHNOLOGIES LIMITED – 0.5 to 6 GHz Bypass E-pHEMT LNA in Wafer Level Package
VMMK-2103
0.5 to 6 GHz Bypass E-pHEMT LNA in Wafer Level Package
Data Sheet
Description
Avago’s VMMK-2103 is an easy-to-use GaAs MMIC bypass
LNA that offers good noise figure and flat gain from 0.5 to
6 GHz in a miniaturized wafer-level package (WLP). The
bias circuit incorporates a power down feature which is
accessed from the input port. This device contains an in-
tegrated bypass switch which engages when the amplifier
is in shut down mode, resulting in an improvement in
the input compression point while consuming minimal
current.
The input and output are matched to 50 Ω (better than 2:1
SWR) across the entire bandwidth; no external matching
is needed. This amplifier is fabricated with enhancement
E-pHEMT technology and industry leading wafer level
package. The WLP leadless package is small and ultra thin
yet can be handled and placed with standard 0402 pick
and place assembly.
WLP 0402, 1mm x 0.5mm x 0.25 mm
CY
Pin Connections (Top View)
Input
/ Vc
CY
Output
/ Vdd
Features
• 1 x 0.5 mm Surface Mount Package
• Ultrathin (0.25mm)
• LNA Bypass function
• 5V Supply
• RoHS6 + Halogen Free
Specifications (at 3GHz, Vd = Vc = 5V, 23mA Typ.)
• Noise Figure: 2.1dB typical
• Loss in Bypass Mode: 2.3dB
• Associated Gain: 14dB
• Input IP3 in Gain Mode: +8dBm
• Input IP3 in Bypass Mode: +21 dBm
• Input P1dB in Gain Mode: 0dBm
• Input P1dB in Bypass Mode: +17dBm
Applications
• Low Noise and Driver for Cellular/PCS and WCDMA
Base Stations
• 2.4 GHz, 3.5GHz, 5-6GHz WLAN and WiMax notebook
computer, access point and mobile wireless applications
• 802.16 & 802.20 BWA systems
• WLL and MMDS Transceivers
• Radar, radio and ECM Systems
Input
Output
/ Vc
Amp
/ Vdd
Attention: Observe precautions for
handling electrostatic sensitive devices.
ESD Machine Model =50V
ESD Human Body Model =125V
Refer to Avago Application Note A004R:
Electrostatic Discharge, Damage and Control.
Note:
“C” = Device Code
“Y” = Month Code