AMMC-6231
16–32 GHz Low Noise Amplifier
Data Sheet
Chip Size: 1900 x 800 µm (74.8 x 31.5 mils)
Chip Size Tolerance: ± 10 µm (± 0.4 mils)
Chip Thickness: 100 ± 10 µm (4 ± 0.4 mils)
RF Pad Dimensions: 110 x 90 µm (4.33 x 3.54 mils)
DC Pad Dimensions: 100 x 100 µm (3.94 x 3.94 mils)
Description
Avago Technologies AMMC-6231 is a high gain,
low-noise amplifier that operates from 16 GHz
to 32 GHz. This LNA provides a wide-band
solution for system design since it covers several
bands, thus, reduces part inventory. The device
has input / output match to 50 Ohm, is
unconditionally stable and can be used as either
primary or sub-sequential low noise gain stage.
By eliminating the complex tuning and assembly
processes typically required by hybrid (discrete-
FET) amplifiers, the AMMC-6231 is a cost-
effective alternative in the 16 - 32 GHz
communications receivers. The backside of the
chip is both RF and DC ground. This helps
simplify the assembly process and reduces
assembly related performance variations and
costs. It is fabricated in a PHEMT process to
provide exceptional noise and gain performance.
For improved reliability and moisture protection,
the die is passivated at the active areas.
Features
• Wide frequency range: 16 - 32 GHz
• High gain: 22 dB
• Low 50 Ω Noise Figure: 2.6 dB
• 50 Ω Input and Output Match
• Flat Gain Response
• Single 3V Supply Bias
Applications
• Microwave Radio systems
• Satellite VSAT, DBS Up/Down Link
• LMDS & Pt-Pt mmW Long Haul
• Broadband Wireless Access (including 802.16 and
802.20 WiMax)
• WLL and MMDS loops
• Commercial Grade Military
AMMC-6231 Absolute Maximum Ratings[1]
Symbol Parameters/Conditions
Vd
Positive Drain Voltage
Vg
Gate Supply Voltage
Id
Drain Current
Pin
CW Input Power
Tch
Operating Channel Temp.
Tstg
Storage Case Temp.
Tmax
Maximum Assembly
Temp (60 sec max)
Units Min. Max.
V
7
V
NA
mA
100
dBm
15
°C
+150
°C -65 +150
°C
+300
Note:
1. Operation in excess of any one of these conditions may result in
permanent damage to this device.
Note: These devices are ESD
sensitive. The following precautions
are strongly recommended. Ensure
that an ESD approved carrier is used
when dice are transported from one
destination to another. Personal
grounding is to be worn at all times
when handling these devices.
For more details, refer to Avago Technologies
Application Note A004R:
Electrostatic Discharge Damage and Control.
ESD Machine Model (Class A)
ESD Human Body Model (Class 0)