English
Language : 

SL1027P_1 Datasheet, PDF (4/8 Pages) AUK corp – DUAL PREAMPLIFIER WITH ALC
SL1027P
Test Method
Sym-
Switch Position
bol SW 1 SW 2 SW 3 SW 4 SW 5
ICCQ
2
OFF OFF
1 OFF
GVO
1
ON OFF 1 OFF
GV
1 OFF ON
1 OFF
VOM
1
OFF ON
1 OFF
THD 1 OFF ON
SW1-1
1→2
CHSEP SW1-2 OFF ON
2→1
VNI
2
OFF ON
1 OFF
1 OFF
1 OFF
AW 1 OFF OFF 2 ON
ACB 1 OFF OFF 2 ON
AD 1 OFF OFF 2 ON
SW 6
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
Measure-
ment
Test Method
Location
-
Read ammeter
a, b
a, b
b
GVO = 20log(VO / VIN ) [dB]
GV = 20log(VO / VIN ) [dB]
Measure output voltage(VO)
at THD=1%
b
Measure distortion factor
at VO=0.5V
b
Measure crosstalk of amp
1,2 at output voltage VO = 0dBm
c
Convert output noise voltage
at 1KHz gain when Rg = 2.2KΩ
Input voltage range from when input
b
voltage VIN =-60dBm until output
voltage VO goes up 3dB
Output voltage VO level difference of
b
amp 1,2 when input voltage VIN =
-20dBm is applied.
b
Measure distortion factor when input
voltage VIN = -20dBm is applied.
Information of Operating
1. ALC Circuit
The ALC circuit is consist of Q1, Q2 and some external components. The output level of
amplifier is rectified by external circuits and this rectified DC level is applied to the ALC
input terminal(Pin 7).
V cc
+
6
5
7
Q1
Q2
+
AMP
2
-
1
4
+
+
Signal
Input
KSI-W021-001
4