English
Language : 

S7805PIC_06 Datasheet, PDF (4/11 Pages) AUK corp – Fixed Voltage Regulator
S78xxPIC
Electrical Characteristics
(Electrical Characteristics at 0℃≤TJ≤125℃and VI =11V, IO =500 ㎃, Unless otherwise specified)
Characteristic
Symbol
Test Condition*
S7806PIC
Unit
Min. Typ. Max.
Output Voltage**
Line Regulation
TJ =25℃
5.75
6
6.25
VO
IO=5 ㎃ ~ 1000 ㎃
VI=8.0V ~ 21V
0℃≤TJ≤125℃ 5.70
6
V
6.30
ÌVO(△VI)
VI=8.0V ~ 25V
VI=9.0V ~ 13V
TJ =25℃
-
5
120
㎷
-
1.5
60
Load Regulation
ÌVO(△IL)
IO=5 ㎃ ~ 1000 ㎃
IO=250 ㎃ ~ 750 ㎃
TJ =25℃
-
14
120
㎷
-
4
60
Quiescent Current
Temperature coefficient of
Output voltage
IQC
△VO/
△Temp
IO=5 ㎃
TJ =25℃
-
4.3
8
㎃
0℃≤TJ≤125℃
-
-0.8
-
㎷/℃
VI = 8.0V ~ 25V
-
Quiescent Current Change
ÌIQC
0℃≤TJ≤125℃
IO = 5 ㎃ ~ 1000 ㎃
-
-
1.3
㎃
-
0.5
Dropout Voltage
Ripple Rejection
Short-Circuit Current Limit
VDROP
RR
ISO
IO=1000 ㎃
f=120 ㎐
VI =9.0V ~ 19V
TJ =25℃
-
2.0
-
V
0℃≤TJ≤125℃
59
75
-
㏈
TJ =25℃
-
0.55
-
A
* Pulse testing techniques are used to maintain the junction temperature as close to the ambient
temperature as possible. Thermal effects must be taken into separately.
** This specification applies only for dc power dissipation permitted by absolute maximum ratings.
KSD-I0T002-000
4