English
Language : 

AT83C5134_14 Datasheet, PDF (91/166 Pages) ATMEL Corporation – Integrated Power Monitor (POR/PFD) to Supervise Internal Power Supply
AT83C5134/35/36
Table 20-5. Status in Master Transmitter Mode
Application software response
Status Status of the Two-
Code wire Bus and Two-
SSSTA wire Hardware
To/From SSDAT
SSSTA
To SSCON
SSSTO SSI
08h
A START condition has
been transmitted
Write SLA+W
X
0
0
A repeated START
10h condition has been
transmitted
Write SLA+W
Write SLA+R
X
0
0
X
0
0
Write data byte
0
SLA+W has been
No SSDAT action
1
18h transmitted; ACK has No SSDAT action
0
been received
No SSDAT action
1
0
0
0
0
1
0
1
0
Write data byte
0
SLA+W has been
No SSDAT action
1
20h transmitted; NOT ACK No SSDAT action
0
has been received
No SSDAT action
1
0
0
0
0
1
0
1
0
Write data byte
0
Data byte has been No SSDAT action
1
28h transmitted; ACK has No SSDAT action
0
been received
No SSDAT action
1
0
0
0
0
1
0
1
0
Write data byte
0
Data byte has been No SSDAT action
1
30h transmitted; NOT ACK No SSDAT action
0
has been received
No SSDAT action
1
0
0
0
0
1
0
1
0
No SSDAT action
0
38h
Arbitration lost in
SLA+W or data bytes
No SSDAT action
1
0
0
0
0
SSAA Next Action Taken by Two-wire Hardware
X SLA+W will be transmitted.
X
SLA+W will be transmitted.
X
SLA+R will be transmitted.
Logic will switch to master receiver mode
X
Data byte will be transmitted.
X
Repeated START will be transmitted.
X
STOP condition will be transmitted and SSSTO flag
will be reset.
X
STOP condition followed by a START condition will
be transmitted and SSSTO flag will be reset.
X
Data byte will be transmitted.
X
Repeated START will be transmitted.
X
STOP condition will be transmitted and SSSTO flag
will be reset.
X
STOP condition followed by a START condition will
be transmitted and SSSTO flag will be reset.
X
Data byte will be transmitted.
X
Repeated START will be transmitted.
X
STOP condition will be transmitted and SSSTO flag
will be reset.
X
STOP condition followed by a START condition will
be transmitted and SSSTO flag will be reset.
X
Data byte will be transmitted.
X
Repeated START will be transmitted.
X
STOP condition will be transmitted and SSSTO flag
will be reset.
X
STOP condition followed by a START condition will
be transmitted and SSSTO flag will be reset.
X
Two-wire bus will be released and not addressed
slave mode will be entered.
X
A START condition will be transmitted when the bus
becomes free.
91
7683C–USB–11/07