English
Language : 

U6046B Datasheet, PDF (5/13 Pages) TEMIC Semiconductors – Rear Window Heating Timer
U6046B
Figure 5. TOGGLE Function
V Batt
R1
C1
510 W
C2
R2
47 mF/
16 V 8
7
6
S1
20 kW
5
U6046B
1
2
3
4
Relay Control Output
Behavior (Pin 2)
Time functions (relay output) can be started or interrupted by the three inputs i.e., ON,
OFF or TOGGLE (pins 3, 4 and 5).
The relay becomes active if the time function is triggered, and the relay contact is inter-
rupted after the elapse of delay time, td. There are two input possibilities:
Toggle Input
When the push-button (TOGGLE) switch, S1, is pressed for the first time, the relay
becomes active after the debounce time, t3, i.e., the relay output, pin 2, is active (see
Figure 5).
Renewed operation of S1 causes the interruption of the relay contact and the relay is
disabled. Each operation of the toggle switch, S1, changes (alters) the condition of the
relay output when the debounce time, t3, is exceeded i.e., the TOGGLE function.
If the relay output is not disabled by pressing the switch S1, the output is active until the
delay time, td, is over.
ON, OFF Inputs (Pins 3 and 4) To avoid simultaneous operation of both inputs, pin 3 (ON) and pin 4 (OFF), use of two-
way contacts with a centre-off position with spring returns (also known as rocker-actu-
ated switch) is recommended (see Figure 6).
Pressing the push-button switch (pin 3-ON) leads to the activation of the relay after the
debounce time, t3, whereas the switching of the Pin 4 switch correspondingly leads to
the relay being de-energized. If the relay is not de-energized by the push-button switch,
it becomes disabled after the delay time, td, is over.
Combined operation, TOGGLE and ON/OFF is not possible because both inputs are
connected to the same debounce stage. Debouncing functions on both edges i.e.,
whenever S1 is ON or OFF.
If pin 3 (input ON) is continuously closed, the delay time, td, still elapses and the relay is
interrupted. This can be used to generate a defined power-on-reset pulse to trigger, for
example, a delay time, td, when the battery voltage, VBatt, is applied.
5
4674A–AUTO–01/03