English
Language : 

T0905 Datasheet, PDF (5/9 Pages) ATMEL Corporation – General- purpose VHF/UHF Power Amplifier (135 to 600 MHz)
T0905 [Preliminary]
Electrical Characteristics (Continued)
Test conditions (if not otherwise specified): VCC = +3.5 V, Tamb = +25°C, 50 Ω input and 50 Ω output match
No. Parameters
Test Conditions
Pin
Symbol Min. Typ. Max. Unit
3.5
Power added
efficiency
VCC = 3.5 V
PRFout = 35.0 dBm
10, 22 -
25, 28
PAE450
50
55
%
3.6
Current consumption PRFout = 35 dBm
active mode
PAE = 55%
10, 22 -
25, 28
I450
1.64
A
3.7 Input VSWR
3.8
Stability/load
mismatch
3.9
2nd harmonic
distortion
PRfin450 = 0 to 8 dBm
PRFout = 31.0 dBm
PRFout450 = 31.0 dBm
VCC = 4.6 V
4
22 - 25
22 - 25
VSWR450
VSWR450
2fo450
2:1
8:1
-35
dBc
3.10
3rd harmonic
distortion
22 - 25
3fo450
-35
dBc
3.11
4th to 8th harmonic
distortion
22 - 25 4fo..8fo450
-35
dBc
3.12
Isolation between
input and output
PRfin150 = 8 dBm
Vctl ≤0.2 V
(power down)
4,
22 - 25
PRFout450
-30
dBm
4 Power Control
4.1 Control curve slope
PRFout ≥ 5 dBm
PRFout ≥ 25 dBm
22 - 25
Sctl
300 350 dB/V
120 150 dB/V
4.2 Power control range Vctl = 0 to 2.5 V
22 - 25
Gctl
60
dB
4.3 Control voltage range
12 - 14
Vctl
0.5
2.0
V
4.4 Control current
PRFin = 0 to 8 dBm
Vctl = 0 to 2.0 V
12 - 14
Ictll
200
µA
*) Type means: A = 100% tested, B = 100% correlation tested, C = Characterized on samples, D = Design parameter
Type*
A
A
C
C
A
A
C
A
C
C
C
A
5