English
Language : 

B10011S_07 Datasheet, PDF (4/12 Pages) ATMEL Corporation – Can Transceiver IC
3. Absolute Maximum Ratings
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress rating
only and functional operation of the device at these or any other conditions beyond those indicated in the operational sections of this
specification is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability.
Parameters
Symbol
Value
Unit
Supply voltage
VCC
–0.5 to +36
V
Controller supply voltage
VDD
–0.5 to +5.5
V
Input voltage at any input
Vin
–0.5 to VDD
V
Junction temperature
Tj
150
°C
Storage temperature range
Tstg
–55 to +150
°C
Soldering temperature (for 10s maximum)
Tsld
260
°C
Operating Conditions
Parameters
Supply voltage car battery
Controller supply voltage
Control input voltage
Input voltage
Operating temperature
Symbol
VCC
VDD
Asel, Bsel
Tx0
Tamb
Value
7 to 32
4.75 to 5.25
0 to VDD
0 to VDD
–40 to +105
Unit
V
V
V
V
°C
4. Operating Modes
0 = 0V, 1 = 5V
Asel
0
Bsel
0
Rx0
3.8V
Mode
H, L drivers disabled, L load disabled, S-, S+ disabled station not in operation, but
consuming current
1
0
From H
Single-wire H, L driver, L load, S-, S+ disabled
0
1
From L
Single-wire L, H driver disabled
1
1
From L-H Two-wire operation, normal mode
ER (error signal) is low when normal operation is disturbed by line faults (interruption, short to
ground or to VCC, H to L short disturbance by high voltage transients). After a waiting period due
to transient delays, the controller is asked to test if single-wire operation is possible by changing
the Asel and Bsel state.
Asel and Bsel have an internal pull-up resistor. Therefore, the no-connect state is 1, but connec-
tion to VDD is recommended when not in use.
4 B10011S
4749D–AUTO–10/07