English
Language : 

AT27C010-70JU Datasheet, PDF (4/13 Pages) ATMEL Corporation – One-time Programmable, Read-only Memory
Table 5-3. DC and operating characteristics for read operation
Symbol Parameter
Condition
Min
Max
Units
ILI
Input load current
VIN = 0V to VCC
Ind.
±1
µA
ILO
Output leakage current
VOUT = 0V to VCC
Ind.
±5
µA
IPP1(2)
VPP(1)) read/standby current
VPP = VCC
10
µA
ISB
VCC(1) standby current
ISB1 (CMOS), CE = VCC± 0.3V
ISB2 (TTL), CE = 2.0 to VCC + 0.5V
100
µA
1
mA
ICC
VCC active current
f = 5MHz, IOUT = 0mA, CE = VIL
25
mA
VIL
Input low voltage
-0.6
0.8
V
VIH
Input high voltage
2.0
VCC + 0.5
V
VOL
Output low voltage
IOL = 2.1mA
0.4
V
VOH
Output high voltage
IOH = -400µA
2.4
V
Notes:
1. VCC must be applied simultaneously or before VPP, and removed simultaneously or after VPP.
2. VPP may be connected directly to VCC, except during programming. The supply current would then be the sum of ICC and
IPP.
Table 5-4. AC characteristics for read operation
Symbol
tACC(3)
tCE(2)
tOE(2)(3)
tDF(4)(5)
tOH
Parameter
Condition
Address to output delay
CE = OE = VIL
CE to output delay
OE = VIL
OE to output delay
CE = VIL
OE or CE high to output float, whichever occurred first
Output hold from address, CE or OE, whichever occurred first
Atmel AT27C010
-45
-70
Min
Max
Min
Max
45
70
45
70
20
30
20
25
7
7
Units
ns
ns
ns
ns
ns
Figure 5-1. AC waveforms for read operation(1)
Notes:
1. Timing measurement reference level is 1.5V for -45 devices. Input AC drive levels are VIL = 0.0V and VIH = 3.0V. Timing measure-
ment reference levels for all other speed grades are VOL = 0.8V and VOH = 2.0V. Input AC drive levels are VIL = 0.45V and VIH = 2.4V.
2. OE may be delayed up to tCE - tOE after the falling edge of CE without impact on tCE.
3. OE may be delayed up to tACC - tOE after the address is valid without impact on tACC.
4. This parameter is only sampled, and is not 100% tested.
5. Output float is defined as the point when data is no longer driven.
4
Atmel AT27C010