English
Language : 

SP200DRL Datasheet, PDF (2/5 Pages) Astrodyne Corporation – 200W Single Output with PFC Function
200W Single Output with PFC Function
SP200/DRL series
INPUT SPECIFICATIONS
Input Voltage Range
Frequency Range
Inrush Current, typ: (cold start)
Input Current, typ
Leakage current
Min Load
Power Factor @ FL
90 ~ 264VAC 120~370 Volts(DC)
47-63 Hz
20Amps/115VAC; 40Amps 230VAC
3.5Amps @115VAC
1.7 Amps @ 230VAC
< 2mAmps / 240VAC
See Selection Chart
PF> 0.93 / 230VAC
0.98 / 115VAC
OUTPUT SPECIFICATIONS
Voltage and Current
Line Regulation
Load Regulation
Voltage Tolerance (Note 2)
Ripple/Noise (Note 1)
Hold Up Time (typ)
Setup, Rise Time
Over Voltage Protection
Over Current Protection
Over Temperature
DC Volt Adjust
See Selection Chart
±0.5%
±0.1%: 3.3~7.5Volts(DC)
±0.5%: 12~48Volts(DC)
±2.0%: 3.3;15Volts(DC)
±1.0%: 24~48Volts(DC)
100mVpk-pk: 3.3~15Volts(DC)
150mVpk-pk: 24;27Volts(DC)
250mVpk-pk: 48Volts(DC)
20mS @ FL
600mS, 30mS @ FL
See Selection Chart
Shut down o/p voltage, re-power
105 ~ 150% rated output power
Constant current limiting,auto recover
95°C ±5°C TSW1: detect on
heatsink of power transistor
Shut down o/p voltage, auto recover
See Selection Chart
GENERAL SPECIFICATIONS
Safety
UL60950-1,
TUV EN60950-1 Approved
Insulation Resistance
≥ 100MΩ / 500Volts(DC)
EMI
Compliance to EN55022 (CISPR22)
Class B
EMS
Compliance to
EN61000-4-2,3,4,5,6,8,11
ENV50204,EN55024,
light Industry Level, Criteria A
Harmonic Current
Compliance to EN61000-3-2,-3
Efficiency
See Selection Chart
Isolation
3000VAC Input - Output
1500VAC Input - Ground
500VAC Output - Ground
ENVIRONMENTAL SPECIFICATIONS
Oper. Temperature
Storage Temperature
Relative Humidity
Temperature Coefficient
MTBF
Vibration
-10°C to +60°C (See Derate Curve)
-20°C to +85°C, 10~95% RH
20~90% RH non cond
0.05% / °C (0-50°C)
183.8KHrs min,MIL-HDBK-217F(25°C)
10~500Hz, 2G10min./1cycle, period for
60min. each along X, Y, Z axes
PHYSICAL SPECIFICATIONS
Size
199x99 x 50mm (7.83”x3.90 ”x1.97”)
Weight
29.99 oz (850g)
NOTE
1. Ripple & noise are measured at 20MHz of bandwidth by using a 12”
twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
2. Tolerance : includes set up tolerance, line regulation and load regula-
tion.
All specifications are typical at nominal input, full load, and 25°C unless other-
wise noted
WWW.ASTRODYNETDI.COM
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458