English
Language : 

RID85 Datasheet, PDF (2/4 Pages) Astrodyne Corporation – 85W Dual Output Switching Power Supply
85W Dual Output Switching Power Supply
RID-85 series
INPUT SPECIFICATIONS
Input Voltage Range
Frequency Range
Inrush Current, typ: (cold start)
Input Current
Leakage current
DC Voltage Adjust
90 ~ 264 VAC; 125~373 Volts(DC)
47-63 Hz
40Amps/230VAC
2.5Amps. @ 115VAC
1.5 Amps. @ 230VAC
< 2mAmps /240VAC
5Volts only: 4.75 ~ 5.5V
OUTPUT SPECIFICATIONS
Voltage and Current
Line Regulation (Note 3)
Load Regulation (Note 4)
Voltage Tolerance (Note 2)
Ripple/Noise (Note 1)
Hold Up Time @ FL
Setup, Rise Time @ FL
Over Voltage Protection
Over Current Protection
Min load
See Selection Chart
See Selection Chart
See Selection Chart
See Selection Chart
See Selection Chart
100mS/230VAC
18mS/115VAC
500ms, 20m/230VAC
1200mS, 30mS/115VAC
5Volts only: 5.75 ~ 6.75VDC
Hiccup mode, auto recover
110 ~ 150% rated output power
Hiccup mode, auto recover
5Volts: 2 ~ 10A / 12-24Volts: 0.3 ~ 5A
GENERAL SPECIFICATIONS
Safety
UL60950-1
TUV EN60950-1 Approved
Insulation Resistance
≥ 100MΩ @ 500VDC
EMI
Compliance to EN55022 (CISPR22)
Class B
Harmonic Current
Compliance to EN61000-3-2,-3
Efficiency
80%(RID-85A) / 81%(RID-85B)
Isolation
3000VAC Input - Output
1500VAC Input - Ground
500VAC Output - Ground
EMS
Compliance to
EN61000-4-2,3,4,5,6,8,11;
ENV50204, EN55024, EN60601-1-2,
heavy industry level, criteria A
ENVIRONMENTAL SPECIFICATIONS
Oper. Temperature
Storage Temperature
Relative Humidity
Temperature Coefficient
MTBF
Vibration
-25°C to +70°C (See Derate Curve)
-40°C to +85°C, 10~95%RH
20 to +90% RH non condi
±0.03% / °C (0-50°C) on +5Voutput
239.4 KHrs min, MIL-HDBK-217F(25°C)
10~500Hz, 5G10min./1cycle, period for
60min. each along X, Y, Z axes
PHYSICAL SPECIFICATIONS
Size
Millimeters
159 x 97 x 38
Inches
6.26” x 3.82 ” x 1.50 ”
Weight
21.16 oz (600g)
Note
1. Ripple & noise are measured at 20MHz of bandwidth by using a 12”
twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
2. Tolerance : includes set up tolerance, line regulation and load regula-
tion.
3. Line regulation is measured from low line to high line at rated load.
4. Load regulation is measured from 20% to 100% rated load, and other
output at 60% rated load.
All specifications are typical at nominal input, full load, and 25°C unless other-
wise noted
WWW.ASTRODYNE.COM
Astrodyne products are not authorized or warranteed for use
as critical components in life support systems, equipment used
in hazardous environments, nuclear controls systems, or other
mission-critical applications.
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458