PMK150E_16 Datasheet, PDF (2/5 Pages) Astrodyne Corporation – 150 Watt Enclosed Switching Power Supply with PFC
150 Watt Enclosed Switching Power Supply with PFC
PMK150E series
INPUT SPECIFICATIONS
ENVIRONMENTAL SPECIFICATIONS
Input Voltage Range
Frequency Range
Power Factor Correction
Inrush Current, typ at cold start:
Leakage Current
90-264 VAC (100-240VAC nom.)
47-63 Hz
0.96 min. at nom. Input
30A @ 115VAC
60A @ 230VAC *
<3.5mA @ 264VAC, 50Hz
OUTPUT SPECIFICATIONS
Voltage and Current (Note 6)
Line Regulation (Note 8)
Load Regulation (20%-FL)
Cross Regulation (note 7)
Preset Accuracy (Note 9)
Ripple/Noise (Notes 1, 3, 10)
Over Voltage Protection
Over Current Protection
Short Circuit Protection
Hold Up Time
See Selection Chart
See Selection Chart
Singles: ± 1%, max.
Duals: ±3/5%
±1%, typ
See Selection Chart
130% max. of nom. input
Auto Recover after fault condition
is removed *
150% max. of FL at nom. input
Auto Recover after fault
condition is removed *
20mS, typ (Nom I/P, FL)
GENERAL SPECIFICATIONS
Isolation (Note 4)
Efficiency
Safety UL/cUL:
UL-EU:
CE:
CB:
I/P-O/P: 4242VDC
I/P-Ground: 2828VDC
O/P-Ground:707VDC
75%, min. at nom. input
UL60950-1 2nd ed./
C22.2 60950-1 2nd ed.
EN60950-1 2nd ed.
EN60601-1-2
IEC60950-1 2nd ed.
Oper. Temperature
Storage Temperature
Relative Humidity
EMC
MTBF
-10 to +70°C
(See Derate Curve)
-25 to +85°C *
0% to +95%, non-cond *
EN55011 Class B
270,000 Hrs
Mil Std 217, 25°C
PHYSICAL SPECIFICATIONS
Size
Construction
Weight
3.17” x 5.5” x 1.6”
Enclosed
1.3 lb, (590g)
NOTES
1. All measurements should be made directly at the terminals of the
power supply
2. All specifications typical @ 25°C, unless otherwise noted, at
nominal line and load.
3. Ripple and noise dependent upon output voltage as specified per
particular model.
4. Isolation for up to 1 minute duration.
5. Specified for free air convection cooling.
6. Minimum load is not required for proper operation.
7. Load Regulation is measured by change ±40% of measured
output load from 60% full load, with the other output set to 60% full
load.
8. Line Regulation measured from 90-264VAC. 100VAC minimum
required for full load start.
9. Preset Accuracy measured at nominal load, 120VAC input.
10. O/P Noise measured directly at the pins/terminals at nominal load,
0.1uF bypass and 47uF electrolytic, pk-pk @ 20MHz bandwidth.
All specifications are typical at nominal input, full load, and 25°C unless other-
wise noted
* These are stress ratings. Exposure of the devices to any of these conditions
may adversely affect long term reliability. Proper operation under conditions
other than the standard operating conditions is neither warranteed nor implied.
WWW.ASTRODYNETDI.COM
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458