English
Language : 

EX-219 Datasheet, PDF (2/9 Pages) Vectron International, Inc – Hi-Reliability Evacuated Miniature Crystal Oscillator
EX-219
Hi-Reliability Evacuated Miniature Crystal Oscillator (EMXO)
Oven Power Consumption (Ioven)
Parameter
Signal
Load
Signal Level (Vol)
Signal Level (Voh)
Rise/Fall Time
Duty cycle
Signal
Load
Output Power (0dBm)
Output Power (+3dBm)
Output Power (+5dBm)
Harmonics
Subharmonics
Spurious
2.0
Watts
0.6
Watts
1.1
Watts
RF Output
Min
Typ
Max. Units
HCMOS
15
pF
0.1
Vs
0.9
Vs
+7
ns
40
60
%
Sinewave
50
Ohm
+0
+2
+4
dBm
+3
+5
+7
dBm
+5
+7
+9
dBm
-30
dBc
-40
dBc
-80
dBc
during warm-up
steady state @ +25°C
steady state @ -40°C
Condition
(10-90%)
(Voh-Vol)/2
50 Ohm load
50 Ohm load
50 Ohm load
Only for Freq from >55 to 120 MHz
Met during qualification (not tested)
Parameter
Tuning Range
EFC Input DC Resistance
Vref
Frequency Tuning (EFC)
Min
Typ
Max. Units
Sufficient to compensate for 10 years aging
100
200
kOhm
+2.4
+2.5
+2.6
VDC
Condition
EFC (0V to Vref)
source current 1 mA maximum
Parameter
Phase Noise (10MHz Output)
ADEV
G-Sensitivity (total gamma)
Additional Parameters [10 to 20 MHz]
Min
Typ
Max. Units
-120
-110
dBc/Hz
-145
-135
dBc/Hz
-150
-145
dBc/Hz
-155
-150
dBc/Hz
2X10-11
1
ppb/g
Condition
10 Hz
100 Hz
1 KHz
10 KHz
Test at 10g sine vibration at 100Hz
Parameter
Phase Noise (40MHz Output)
ADEV
G-Sensitivity (total gamma)
Additional Parameters [>20 to 55 MHz]
Min
Typ
Max. Units
-100
-90
dBc/Hz
-130
-120
dBc/Hz
-145
-140
dBc/Hz
-150
-145
dBc/Hz
5X10-11
1
ppb/g
Condition
10 Hz
100 Hz
1 KHz
10 KHz
Test at 10g sine vibration at 100Hz
Parameter
Phase Noise (100MHz Output)
ADEV
G-Sensitivity (total gamma)
Additional Parameters [>55 to 120 MHz]
Min
Typ
Max. Units
-90
-85
dBc/Hz
-125
-115
dBc/Hz
-140
-135
dBc/Hz
-145
-140
dBc/Hz
5X10-11
1
ppb/g
Condition
10 Hz
100 Hz
1 KHz
10 KHz
Test at 10g sine vibration at 100Hz
Radiation Tolerant (operating)
Mechanical Shock (non operating)***
Vibration Random (non operating)***
Vibration Sine (non operating)***
Storage Temperature***
Note: *** Met during qualification
Environmental Conditions (Qualified to meet)
Active devices are selected from product families that are inherently radiation tolerant to meet
100krad (Si) Total Ionizing Dose
MIL-STD-202, Test Method 213, Condition E (1000G, 0.5msec)
MIL-STD-202, Test Method 214, Condition I-H (30Grms, 3 minutes/axis)
MIL-STD-202, Test Method 204, Condition D (20Gpk, 20 minutes/axis)
-55°C minimum and +85°C maximum
Vectron International • 267 Lowell Road, Hudson, NH 03051 • Tel: 1-88-VECTRON-1 • http://www.vectron.com