English
Language : 

DUP75_16 Datasheet, PDF (2/3 Pages) Astrodyne Corporation – Isolated and Unregulated 0.75 WATT Modular DC/DC Converters
Isolated and Unregulated 0.75 WATT Modular DC/DC Converters
DUP75 series
INPUT SPECIFICATIONS
ENVIRONMENTAL SPECIFICATIONS
Input Voltage Ranges:
5 VDC Nominal
12 VDC Nominal
15 VDC Nominal
24 VDC Nominal
4.5-5.5 VDC
10.8-13.2 VDC
13.5-16.5 VDC
21.6-26.4 VDC
OUTPUT SPECIFICATIONS
Voltage and Current
Load Regulation
10% - FL
Line Regulation
Temperature Coefficient
Ripple/Noise(Single/Dual)
Voltage Stability
Short Circuit Protection
See Selection Chart
+/- 10% on 5V output
+/- 6% on all others
+/- 1.2%/1% of Vin
+/-0.1%/DegC
50mV Pk-Pk, typ
+/-5%, max
1 Second max
Oper. Temperature
Storage Temperature
Maximum Case Temp
MTBF
-25 to +71 DegC(FL)
-55 to +125 DegC *
110 DegC *
5.5 MHrs
MIL-HDBK 217F TA=25C FL
PHYSICAL SPECIFICATIONS
Case Material
Construction
Non-Conductive Black Plastic
Fully Encapsulated
GENERAL SPECIFICATIONS
Input-Out Isolation
Efficiency
Switching Frequency
Isolation Resistance
750VDC
78%, typ
100Khz
10000 M Ohms
All specifications are typical at nominal input, full load, and 25DegC unless
otherwise noted
* These are stress ratings. Exposure of the devices to any of these conditions
may adversely affect long term reliability. Proper operation under conditions
other than the standard operating conditions is neither warranteed nor implied.
WWW.ASTRODYNETDI.COM
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458