AHP101 Datasheet, PDF (2/3 Pages) Astrodyne Corporation – 100W Medical Adapters for Health Care Applications with PFC CISPR-11EN55011classBemissionLimitsandaredesignedto
100W Medical Adapters for Health Care Applications with PFC
AHP101 series
INPUT SPECIFICATIONS
PHYSICAL SPECIFICATIONS
Input Voltage Range
90-260 VAC (100-240 Nominal)
Frequency Range (Sine Wave) 47-63 Hz
Input Current
Low Line (100VAC)
1.2A max.
High Line (240VAC) 0.5A max.
No Load Power Consumption 0.5W
Inrush Current, typ (Cold Start) Low Line (100VAC)
50A max.
High Line (240VAC) 120A max.
Leakage Current (240Vin, 60hHz) 0.25mA max.
Power Factor Correction
0.95 min.
Protection Class
Class I
OUTPUT SPECIFICATIONS
Voltage and Current
Output Power Range
Load Regulation (Note 2)
Line Regulation (Note 1)
Over Load Protection*
Over Voltage Protection*
Short Circuit Protection
Transient Response
Temperature Coefficient
Ripple/Noise (Note 3)
Start Up / Hold Up Time
See Selection Chart
0 to FL Rating, 100W max.
± 5%, max. (0-FL, 230Vin)
± 1%, max., FL
110-150%, Auto Recovery
112-132%
Auto Recovery
110Vin, FL to 1/2L
4mS
±0.04%/°C, typ
100mV p-p
100Vin, FL 2S max. / 16mS min.
Size
Construction
Weight
Output Connector
Flammability Rating
5.75” x 2.99” x 1.69”
(146 x 76 x 43mm)
Desktop Style
23.63oz (670g)
See Selection Chart
UL94V-1
ENVIRONMENTAL SPECIFICATIONS
Oper. Temperature
Cooling
Storage Temperature
Operating/Storage Humidity
EMC
MTBF (MIL-HDBK-217F)
Surge Voltage
ESD - Air
ESD - Contact
Operating Altitude (Elevation)
Vibration
-10 to +40°C (FL) *
50% Load @ 70°C
(See Derate Curve Last Page)
Free Air Convection
-40 to +85°C, 10~95% RH *
0% to 95%, non-cond *
Compliance to EN55011 (CISPR11),
EN61000-3-2, -3 Class B
100,000 Hrs
2kV
IEC61000-4-2, 8kV
IEC61000-4-2, 6kV
3000m
5G, 10 ~ 500Hz, 10min./1cycle,
60min. each along X, Y, Z axes
GENERAL SPECIFICATIONS
Input-Out Isolation
Input-GND Isolation
Isolation Resistance
Efficiency (FL, Nom. Vin)
Safety
4000 VAC
1500 VAC
50MΩ, 500VDC,25°XC/ 70% RH
See Selection Chart
ANSI/AAMI ES 60601-1:2005
(UL/cUL 3rd Edition),
EN 60601-1:2006
(TUV/T-mark 3rd Edition)
NOTES
1. Line regulation is defined by changing ±10% of input voltage from
nominal line at rated load.
2. Load regulation is defined by changing ±40% of measured output
load from 60% rated load.
3. Ripple & noise is measured by using 20MHz bandwidth limited
oscilloscope and terminated each output with a 0.47uF capacitor at
rated load and nominal line.
All specifications are typical at nominal input, full load, and 25°C unless other-
wise noted
* These are stress ratings. Exposure of the devices to any of these conditions
may adversely affect long term reliability. Proper operation under conditions
other than the standard operating conditions is neither warranteed nor implied.
WWW.ASTRODYNETDI.COM
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458