SUU61 SERIES
63W U-bracket Switching Power Supplies For I.T.E.
Description:
The SUU61 series of compact, open frame constructed, AC/DC
switching mode power supplies provide 63 Watts of continuous
output power .They are ideally suited for use in CRT terminals
,disc drive systems, microprocess or based systems, portable
equipments and many other applications. All models meet FCC
Part-15 class B and CISPR-22 class B emission Limits and are
designed to comply with UL/c-UL(UL 60950),ITS/GS(EN 60950)
and new CE requirements. All units are 100% burned in and
tested.
Features:
Wide Input Voltage 90 to 264 VAC,47 to 63 Hz
Internal EMI filter
Single to Quad Output
Input connector mates with Molex housing 09-50-3031 and
Molex 2878 series crimp terminal
Output connector mates with Molex housing 09-50-3061
(or 09-50-3081) and Molex 2878 series crimp terminal
Output Voltage Available From 3 VDC Thru 50 VDC
Input Surge Current, Over Voltage and Over Load protection
Class I Insulation
Two Years Warranty
Electrical Characteristics:
Safety Approvals :
ITS Bauart
Testing & gepruft
Certification
CB
Sym.
Parameter
Test Conditions
Min. Typ. Max. Unit
Vin
Fin
Wo
Vo
Io
Iil
Iih
Irl
Irh
Eff
REG-i
REG-o
OVP
OCP
Ttr
Thold
Ts
Vrn
Ilk
Tc
Input Voltage
Operating Voltage
90
264
Input Frequency
47
63
Output Power Range
Vin=90 to 264VAC
0
63
Output Voltage Range
See rating chart
Output Current Range
See rating chart
Input Current (Low Line)
Io=Full load, Vin=115VAC
1.6
Input Current (High Line) Io=Full load, Vin=230VAC
1.0
Low Line Inrush Current
Io=Full load, 25°c, Cool start,
Vin=115VAC
12 15
High Line Inrush Current
Io=Full load, 25°c, Cool start,
Vin=230VAC
26 30
Efficiency
Io=Full Load, Vin=230VAC
70 80 88
Line Regulation
Io=Full Load
0.5 1
Load Regulation
Vin=230VAC
36
Over Voltage Protection
112
132
Over Current Protection
110
150
Transient Response
Io=Full Load to Half Load, Vin=100VAC
4
Hold-Up Time
Io=Full Load, Vin=110VAC
12
Start Up Time
Io=Full Load, Vin=100VAC
0.3 1 2
Ripple & Noise (Pe ak to Peak) Full Load, Vin=90VAC
12
Safety Ground Leakage Curr ent Io=Full Load, Vin=240VAC
0.4 0.45
Temperature Coefficient
All output
-0.04
0.04
VAC
Hz
W
V
A
A
A
A
A
%
%
%
%
%
mS
mS
S
%
mA
%/°c
Environmental :
Sym.
Parameter
Te s t Conditions
Toper Operating Temperature
Tstg Storage Temperature
Hr Relative Humidity
Pd Derate linearly from 100% load at 40 C to 50% load at 70 C
Min. Typ. Max.
0
70
-40
85
5
95
Unit
C
C
%
Safety Specifications:
Sym.
Parameter
Vps
Dielectric Withstanding Voltage
for Primary to secondary
Dielectric Withstanding Voltage
Vpg for Primary to Ground
Ri Isolation Resistance
CISPR EMI requirements for CISPR-22
FCC EMI requirements for FCC PART-15
Te s t Conditions
Primary to secondary
Primary to ground
Test Voltage=500VDC
Vin=220VAC
Vin=110VAC
Min. Typ. Max. Unit
4242
VDC
2121
50
B
B
VDC
M
CLASS
CLASS