English
Language : 

SUU100 Datasheet, PDF (1/2 Pages) Astrodyne Corporation – 1000W U-bracket Switching Power Supplies For I.T.E.
SUU100 SERIES
100W U-bracket Switching Power Supplies For I.T.E.
Description:
The SUU100 series of compact, open frame constructed, AC/DC
switching mode power supplies provide 100 Watts of continuous output
power .They are suited for use in based systems, portable equipments
and many other applications. All models meet FCC Part-15 class B and
CISPR-22 class B emission Limits and are designed to comply with
UL/c-UL(UL 60950-1:2ndEdition),TUV/Bauart(EN 60950-1:2ndEdition)
and new CE requirements. All units are 100% burned in and tested.
Features:
Wide Operating Voltage 90 to 260 VAC,47 to 63 Hz
Internal EMI filter
Single Output
Input connector mates with Molex housing 09-50-3051 and
Molex 2478 series crimp terminal
Output connector mates with Molex housing 09-50-3131 and
Molex 2478 series crimp terminal
Input Surge Current, Over Voltage and Over Load protection
Over Voltage Protection (Crowbar Design)
Active Power Factor Correction
Class I
2 year warranty
Safety Approvals :
BAUART
GEPRUFT
TYPE
Product Safety APPROVED
CB
Electrical Characteristics:
Sym.
Parameter
Test Conditions
Min. Typ. Max. Unit
Safety Approvals Input
Vin Voltage Range
Operate Voltage Range
100
240 VAC
90
260 VAC
fin Input Frequency
47
63 Hz
PF Power Factor Correction
Io=Full load, Vin=90~260VAC
0.95 0.97 1.0
Po Output Power Range
Vo Output Voltage Range
Io Output Current Range
Vin=90 to 260 VAC
0
100 W
See rating Chart V
See rating Chart A
Iil
Iih
I rl
I rh
Eff
Input Current (Low Line)
Input Current (High Line)
Low Line Inrush Current
High Line Inrush Current
Efficiency
Io=Full load, Vin=115VAC
Io=Full load, Vin=230VAC
Io=Full load, 25 C,Cool start,
Vin=115VAC
Io=Full load, 25 C,Cool start,
Vin=230VAC
Io=Full load, Vin=230VAC
1.6 A
0.8 A
44 50 A
88 100 A
70 80 85 %
REG-i Line Regulation
Io=Full load
0.5 1
%
REG -o Load Regulation
Vin=230VAC
3
5
%
OVP Over Voltage Protection
112
132 %
OCP Over Current Protection
110
150 %
Ttr Time of Transient Response Io=Full load to Half Load, Vin=100VAC
4
mS
Thold Hold-Up Time
Io=Full load, Vin=110VAC
16
mS
Ts
* Vp-p
Ilk
Start Up Time
Io=Full load, Vin=100VAC
Ripple & Noise (Peak to Peak) Full load, Vin=90VAC
Safety Ground Leakage Current Io=Full load, Vin=240VAC
2
S
0.5 1
%
0.5 0.75 mA
TC Temperature Coefficient All output
-0.04
0.04 %/ C
* Note: The Ripple & Noise which is under 3.3VDC at 2% max
Environmental :
Sym.
Parameter
Toper Operating Temperature
T e s t Conditions
Tstg Storage Temperature
Ho Operating Humidity
Hr Storage Humidity
MTBF Operating Temperature at 25 C, Calculated per MIL-HDBK-217F
Pd Derate linearly from 100% load at 50 C to 50% load at 70 C
Min. Typ. Max.
0 50 70
-40
85
0
95
0
75
0.1M
Unit
C
C
%
%
Hrs