English
Language : 

SPU131 Datasheet, PDF (1/2 Pages) Astrodyne Corporation – 20W Desk Top Switching Power Supplies For I.T.E
SPU131 SERIES
130W Desk Top Switching Power Supplies For I.T.E.
Description:
The SPU131 series of AC/DC switching mode power supplies
provide 130 Watts of continuous output power . All supplies
are UL94V-1 min compliant. They are suited for a variety of
applications. All models meet FCC Part-15 class B and CISPR-
22 En55022 class B emission Limits and are designed to
comply with UL/c-UL(UL 60950-1:2ndEdition) ,TUV/T-mark
(EN 60950-1:2ndEdition) and new CE requirements. All units
are 100% burned in and tested.
Features:
Wide Operating Voltage 90 to 260 VAC,47 to 63 Hz
IEC-320-C14 Input Inlet
Single Output
Optional Output Connector (See appendix)
Input Surge Current, Over Voltage And Over Load protection
Output Voltage Protection (Crowbar Design)
Active Power Factor Correction
Class I
Energy Star 2.0, Efficiency level V
ON/OFF SWITCH (Optional)
2 year warranty
Electrical Characteristics:
Safety Approvals :
S&E
RT
PS Agree to apply for the
E PSE if order on hand
Sym.
Parameter
Test Conditions
Min. Typ. Max. Unit
Vin
fin
PF
Po
Vo
Io
Iil
Iih
I rl
I rh
Eff
REG-i
REG -o
OVP
OCP
Ttr
Thold
Ts
Vp-p
Ilk
TC
Safety Approvals Input
Voltage Range
100
240
Operate Voltage Range
Input Frequency
Power Factor Correction
Output Power Range
Output Voltage Range
Output Current Range
Input Current (Low Line)
Input Current ( High Line)
Io=Full load, Vin=230 VAC
Vin=90 to 260 VAC
Io=Full load, Vin=115 VAC
Io=Full load, Vin=230 VAC
90
260
47
63
0.95
1
0
130
See rating chart
See rating chart
1.40
0.70
Low Line Inrush Current
Io=Full load, 25 C ,Cool start,
Vin= 115VAC
30
Io=Full load, 25 C ,Cool start,
High Line Inrush Current
50
Vin= 230VAC
Efficiency
Io=Full Load, Vin=230VAC
87
89
Line Regulation
Io=Full Load
0.5 1
Load Regulation
Vin=230VAC
5
Over Voltage Protection
112
132
Over Current Protection
110
150
Time of Transient Response Io=Full Load to Half Load, Vin=100VAC
4
Hold-Up Time
Io=Full Load, Vin=110VAC
16
Start Up Time
Io=Full Load, Vi n= 10 0V AC
2
Ripple & Noise (Peak to Peak) Full Load, Vin=90VAC
1
Safety Ground Leakage C urrent Io = Fu ll Load, V i n = 240 V A C/60Hz
0.75
Temperature Coefficient
All output
-0.04
0.04
VAC
VAC
Hz
W
V
A
A
A
A
A
%
%
%
%
%
mS
mS
S
%
mA
%/ C
Environmental :
Sym.
Parameter
Toper Operating Temperature
T e s t Conditions
Tstg
Ho
Hr
Storage Temperature
Operating Humidity
Storage Humidity
MTBF Operating Temperature at 25 C, Calculated per MIL-HDBK-217F
Pd Derate linearly from 100% load at 40 C to 50% load at 70 C
Min. Typ. Max.
0 40 70
-40
85
0
95
0
75
0.1M
Unit
C
C
%
%
Hrs