English
Language : 

ANC Datasheet, PDF (1/3 Pages) Astrodyne Corporation – 15 Watt Ultraminiature Modular Switching Power Supplies
1 5 WaAt tNUCl tSrEaRmIi nEiSa t u r e M o d u l a r S w i t c h i n g P o w e r S u p p l i e s
KEY FEATURES
� Switching Power Module for PCB Mountable
� Fully Encapsulated Plastic Case
� Universal Input Range 90-264VAC, 47-440 Hz
� Regulated Output
� Low Ripple and Noise
� High Efficiency
� CE, cUL, TUV Approvals
� 2-Year Product Warranty
VER : A_0 update : 94.03.21
AC-DC Power Module
A N C 15 Wattsse r i e s
ELECTRICAL SPECIFICATIONS
Model No. ( Single Output )
Max Output Wattage (W)
Voltage
Frequency (Hz)
Input
Current (Full load)
Inrush Current (<2ms)
Leakage Current
External Fuse (recommend)
Voltage (V.DC.)
Voltage Accuracy
Current (mA) max
Line Regulation (LL-HL) (typ.)
Load Regulation (5-100%) (typ.)
Output
Minimum Load
Maximum Capacitive Load
Ripple
Noise
Efficiency
Hold-up Time
Switching Frequency
Over Power Protection
Protection
Over Voltage Protection
Short Circuit Protection
Input-Output (V.AC)
Isolation
Input-FG (V.AC)
Output-FG (V.AC)
Operating Temperature
Storage Temperature
Environment Temperature Coefficient
Humidity
MTBF
Dimension (L x W x H)
Physical
Case Material
Weight
Cooling Method
Safety
Agency Approvals
EMC
EMI (Conducted & Radiated Emission)
EMS (Noise Immunity)
ANC-5S
ANC-12S
ANC-15S
ANC-24S
15W
15W
15W
15W
90-264 VAC or 120-370 VDC
47-440 Hz
280 mA max. (115 VAC) / 170 mA max. (230 VAC)
10 A max. (115 VAC) /20 A max. (230 VAC)
0.75 mA max.
1.5 A slow blow type
5V
12V
15V
24V
±2%
3000
1250
1000
625
±0.5%
±0.5%
0%
470-23,000µF depending on model
<0.2% Vout +40mV max (Vp-p)
<0.5% Vout +50mV max (Vp-p)
70%
73%
73%
77%
15 ms min.
100 kHz
Hiccup technique, auto-recovery
Zener diode clamp
Hiccup mode, indefinite (automatic recovery)
3000V
1500V
500V
-25°C…+70°C (with derating)
-40°C…+85°C
±0.02%/°C
95% RH
>200,000 h @ 25°C (MIL-HDBK-217F)
2.91 x 2.13 x 0.87 Inches ( 74.0 x 54.0 x 22.0 mm ) Tolerance �0.5 mm
Plastic resin with Fiberglass (flammability to UL 94V-0)
140 g
Free air convection
UL/cUL, CE, TUV
EN 55022 class B
EN 55024
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
-1-
WWW.ASTRODYNE.COM
300 Myles Standish Blvd., Taunton, MA 02780
Ph: 1-800-823-8082
Fax: 508-823-8181