English
Language : 

ALO10B48N-6S Datasheet, PDF (7/30 Pages) Astec America, Inc – AEO40x48 / ALO40x48 Single Output 8th Brick: Baseplate or Open-Frame Module
Technical Reference Notes
AEO_ALO40/35/30/20/10x48 Series
(Single Output 8th Brick)
Basic Operation and Features
INPUT UNDER VOLTAGE LOCKOUT
To prevent any instability to the converter, which may affect the end system, the converter have been designed to turn-on once VIN
is in the voltage range of 33-36 VDC. Likewise, it has also been programmed to turn-off when VIN drops down to 31-34 VDC.
OUTPUT VOLTAGE ADJUST/TRIM
The converter comes with a TRIM pin (PIN 6), which is used to adjust the output by as much as 90% to 110% of its set point. This
is achieved by connecting an external resistor as described below.
To INCREASE the output, external Radj_up resistor should be
connected between TRIM PIN (Pin6) and +SENSE PIN (Pin 7).
Please refer to Equation (1) for the required external resistance
and output adjust relationship.
Equation (1a): 1.5V to 12V
Radj_up
=
5.1 ×


Voset × (100 +
1.225× ∆%
∆%)
−
510
∆%

− 10.2

ΚΩ
Equation (1b): 1.2V
Radj_up
=
5.1 ×


Voset ×
0.6 ×
(100 +
∆%
∆%)
−
510
∆%
−

10.2

ΚΩ
Figure 3. External resistor configuration to increase the o/p.
To DECREASE the output, external Radj_down resistor should be
connected between TRIM pin (Pin 6) and
-SENSE PIN (Pin 5). Please refer to Equation (2) for the
required external resistance and output adjust relationship.
Equation (2):
Radj_down

510
∆%
−
10.2⋅kΩ
Where: ∆% = percent change in output voltage
Figure 4. External resistor configuration to decrease the o/p.
OUTPUT ENABLE
The converter comes with an Enable pin (PIN 2), which is primarily used to turn ON/OFF the converter. Both a Positive (no “N”
suffix required) and a Negative (suffix “N” required) Enable Logic options are being offered. Please refer to Table 2 for the Part
Numbering Scheme.
For Positive Enable, the converter is turned on when the Enable pin is at logic HIGH or left open. The unit turns off when the
Enable pin is at logic LOW or directly connected to -VIN. On the other hand, the Negative Enable version turns unit on when the
Enable pin is at logic LOW or directly connected to -VIN. The unit turns off when the Enable pin is at Logic HIGH.
MODEL: AEO40x48 / ALO40x48 SERIES
JUNE 24, 2005 - REVISION B
SHEET 7 OF 30