English
Language : 

ALQ40_03 Datasheet, PDF (6/16 Pages) Astec America, Inc – Industry Standard ¼ Brick: 36V-75V Input / 50A Output Current
Technical Reference Notes
ALQ40/50 Series
(Open Frame Single Output Quarter Brick)
Electrical Specifications (continued)
FEATURE SPECIFICATION
Parameter
Output Enable ON/OFF10
Device Symbol
Min
Negative Enable ("N" suffix)
N
-
0
Enable Pin voltage for Module ON suffix
-
2.95
Module OFF
Positive Enable (No suffix)
Enable Pin voltage for Module ON No
-
2.95
Module OFF suffix
-
0
Output Voltage Remote Sensing11,13
All
-
-
Output Voltage Trim Range12,13
All
90
Typ
Max
Unit
-
1.2
V
-
20.0
V
-
20.0
V
-
1.2
-
10
%VO
110
%VO
Note:
10. See Appendix A.3 for the recommended/ appropriate Module Enable configuration.
11. The sense pins can be used to compensate for any voltage drops (per indicated max limits) that may
occur along the connection between the output pins to the load. Pin 7 (+Sense) and Pin 5
(-Sense) should be connected to Pin 8 (+Vout) and Pin 4 (Return) respectively at the point where
regulation is desired.
12. Refer to Equation (1) and (2) and Figures 3 and 4 for the Output Trim Adjust configuration.
13. The combination of remote sense and Trim adjust cannot exceed 110% of VO, NOM.
ISOLATION SPECIFICATION
Parameter
Isolation Capacitance
Isolation Resistance
Device Symbol
Min
All
-
-
All
-
10
Typ
Max
Unit
2.70
-
nF
-
-
MΩ
SAFETY APPROVAL
The ALQ50 series have been certified through:
• UL + cUL 60950, Third Edition - Recognized (PENDING)
• EN 60950 through TUV-PS (PENDING)\
• Basic Insulation
MODEL: ALQ50 SERIES
APRIL 21, 2003 - REVISION A (PRELIMINARY)