English
Language : 

AK45C Datasheet, PDF (10/17 Pages) Astec America, Inc – 36 Vdc to 75 Vdc Inputs, 100 W
Technical Reference Notes (TRN)
Test Configurations
AK45C 100W Series
36 Vdc to 75 Vdc Inputs, 100 W
TO OSCILLOSCOPE
BATTERY
Ltest
12 uH
Cs 220 uF
ESR < 0.1 OHM
@ 20 ºC, 100 kHz
33 uF
ESR < 0.7 OHM
@ 20 ºC, 100 kHz
Vi(+)
Vi(-)
Note: Measure input reflected-ripple current with a simulated source inductance (Ltest) of 12 uH. Capacitor
Cs offsets possible battery impedance. Measure current as shown above.
Figure 10. Input Reflected-ripple Test Setup.
Vo(+)
Vo(-)
COPPER STRIP
0.1 uF
10 uF SCOPE
RESISTIVE
LOAD
Note: Use a 0.1 uF ceramic capacitor and a 10 uF tantalum capacitor. Scope measurement should be made
using a BNC socket. Position the load between 51 mm and 76 mm (2 in. and 3 in.) from module.
Figure 11. Peak-to-Peak Output Noise Measurement Test Setup.
_____________________________________________________________
ASTEC POWER - Andover
10 of 17