NTS350 Datasheet, PDF (1/2 Pages) Astec America, Inc – 350 Watts
350 Watts
Total Power:
Input Voltage:
NTS350 Series # of Outputs:
200-350 Watts
85-264 VAC
120-300 VDC
Single
Special Features
• Active power factor correction
• IEC EN6100-3-2 compliance
• Remote sense
• Power fail and remote inhibit
• Single wire current sharing
• Built-in EMI filter
• Low output ripple
• 5V standby
• 12V fan output
• Overvoltage protection
• Overload protection
• Thermal overload protection
• DC power good
• Built in OR-ing diode / FET
• Optional fan cover (-CF suffix)
Environmental
Operating temperature: 0° to 50°C ambient
derate each output at 2.5% per degree from 50° to
70°C
Electromagnetic susceptibility: Designed to meet
EN61000-4, -2, -4, -5, -11 Level 3
Humidity: Operating; non-condensing
10% to 90%
Vibration: Three orthogonal axes, sweep at
1 oct/min, 5 min. dwell at four major resonances
2 G peak 8 Hz to 500 Hz, operational
Storage temperature: -40° to 85°C
Temperature coefficient: ±.04% per °C
MTBF demonstrated: >1M hours at full load and
25°C ambient conditions
Electrical Specs
Input
Input range
Frequency
Inrush current
Efficiency
EMI filter
Power factor
Safety ground
leakage current
85-264 VAC; 120-300 VDC
47-440 Hz
38 A max., cold start @ 25°C
85% typical at full load
FCC Class B conducted and radiated
CISPR 22 Class B conducted and radiated
EN55022 Class B conducted and radiated
VDE 0878 PT3 Class B conducted and
radiated.
0.99 typical
<0.5 mA @ 50/60 Hz, 264 VAC input
Output
Maximum power
Adjustment range
Standby output
Fan output
Hold-up time
Overload protection
Overvoltage protection
200W convection; 350 W with 30 CFM
forced air
±5%
5 V @ 2A regulated, ±5%
12 V @ 1A, -5 %, +7%, 0.5A for -CF version
20 ms @ 350 W load, 115 VAC nominal
line at factory voltage setting
Short circuit protection on all outputs.
Case overload protected @ 115-130%
above peak rating
20% to 35% above nominal output
Logic Control
Power failure
Remote on/off
DC OK
Remote sense
TTL logic signal goes high 100-500 msec
after main output. It goes low at least 4
msec before loss of regulation
Requires an external contact closure to
inhibit outputs
TTL logic goes high after the output is in
regulation. It goes low when there is loss
of regulation.
Compensates for 0.5 V lead drop min.
Will operate without remote sense
connected. Reverse connection protected.
TUV
UL
CSA
NEMKO
AUSTEL
CB
CE
Safety
60950
60950
60950
60950
60950
Certificate and report
Mark (LVD)
1