English
Language : 

LPS120 Datasheet, PDF (1/3 Pages) Astec America, Inc – 120 Watts
Embedded Power for
Business-Critical Continuity
LPS120 Series
120 Watts
Total Power:
Input Voltage:
# of Outputs:
80 - 130 Watts
85 - 264 VAC
Single
RoHS
Rev. 5.09.06
LPS120 Series
1 of 3
Special Features
• Active power factor correction
• 3" x 5" footprint
• Less than 1U high
• EN61000-3-2 compliant
• Remote sense
• Power fail and remote inhibit
• Single wire current sharing
• Adjustable main output
• Built-in Class B EMI filter
• Overvoltage protection
• Overload protection
• Thermal overload protection
• 5 V Standby output
and 12V Fan output
Safety
TUV
UL
CSA
NEMKO
AUSTEL
CB
CE
60950
60950
60950
60950
60950
Certificate and report
Mark (LVD)
Electrical Specifications
Input
Input range
Frequency
Inrush current
Efficiency
EMI/RFI
Power factor
Safety ground
leakage current
85 - 264 VAC ; 127 - 300VDC
47-440 Hz
40A max., cold start @ 25°C
80% typical at full load
FCC Class B conducted; CISPR22 Class B conducted; EN55022
Class B conducted; VDE0878PT3 Class B conducted
0.99 typical
0.5mA @ 50/60 Hz, 264 VAC input
Output
Maximum power
80W for convection ; 130W with 30CFM forced air
Adjustment range
±5% minimum on the main outputs
Fan output
12V @ 500mA - 5%, +7%
Standby outputs
5V @ 500mA ±5%
Hold-up time
20ms @ 125W load, 120VAC input
Overload protection Short circuit protection on all outputs. Case overload protect-
ed @ 120-135% above rating
Overvoltage protection 20-35% above nominal output
Remote sense
Logical Control
Compensates for 0.5 V lead drop max. Will operate without
remote sense connected. Reverse connection protected.
Power failure
TTL logic signal goes high 100-500 msec after main output; it
goes low at least 4 msec before loss of regulation
Remote inhibit
Requires a contact closure to disable the outputs, except 5V
standby.
Remote sense
Compensates for 0.5 V lead drop min. Will operate without
remote sense connected. Reverse connection protected.