English
Language : 

LPQ250 Datasheet, PDF (1/2 Pages) Astec America, Inc – 250 Watts
250 Watts
LPQ250 Series
Total Power: 250 Watts
Input Voltage: 85-264 VAC
120-300 VDC
# of Outputs: Quad
Electrical Specs
Input
Input range
Frequency
Inrush current
Efficiency
EMI filter
Power factor
Safety ground leakage
current
85-264 VAC; 120-300 VDC
47-440 Hz
20 A max., cold start @ 25°C
75% typical at full load
FCC Class B conducted and radiated
CISPR 22 Class B conducted and radiated
EN55022 Class B conducted and
radiated
VDE 0878 PT3 Class B conducted and
radiated.
0.99 typical
<0.5 mA @ 50/60 Hz, 264 VAC input
Special Features
Output
• Active power factor correction
• IEC EN61000-3-2 compliance
• Remote sense on main output
• Power fail and remote inhibit
• Single wire current sharing
• Built-in EMI filter
• Adjustable floating 4th output
• 2 Supervisory outputs 5 V and 12 V
• Overvoltage protection
• Overload protection
• Thermal overload protection
• DC power good
• Cover -C
• 120 KHz switching frequency
• Optional with fan cover -CF
• Optional end fan cover -CEF
Environmental
Operating temperature: 0° to 50°C ambient
derate each output at 2.5% per degree from
50° to 70°C
Electromagnetic susceptibility: Designed to
meet IEC 801, -2, -3, -4, -5, -6, Level 3
Humidity: Operating; non-condensing
5% to 95%
Vibration: Three orthogonal axes, sweep at
1 oct/min, 5 min. dwell at four major
resonances 0.7 G peak 5 Hz to 500 Hz,
operational
Storage temperature: -40° to 85°C
Temperature coefficient: ±.04% per °C
MTBF demonstrated: >550,000 hours at full
load and 25°C ambient conditions
Maximum power
Adjustment range
Supervisory outputs
Hold-up time
Overload protection
Overvoltage protection
Logic Control
Power failure
Remote on/off
DC-OK
Remote sense
With cover: 250 W with 30 CFM forced
air,
(-C) (-CF) (-CEF).
±5% min. on main: 5-25 V on 4th output
5 V @ 100 mA regulated, 12 V @ 500
mA
16 ms @ 250 W load, 115 VAC nominal
line
Short circuit protection on all outputs.
Case overload protected @ 110-145%
above peak rating
5 V output: 5.7-6.7 VDC.
TTL logic signal goes high 50-150 msec
after 5V output. It goes low at least 4
msec before loss of regulation
Requires an external contact (N.O or
N.C) to inhibit outputs
TTL logic goes high 50-150 msec after 5
V output. It goes low when there is loss
of regulation.
Compensates for 0.5 V lead drop min.
Will operate without remote sense
connected. Reverse connection
protected.
Safety
VDE 0805/EN60950 (IEC950)
UL
UL1950
CSA CSA 22.2-234 Level 5
NEMKO EN 60950/EMKO-TUE
(74-sec) 203
CB
Certificate and report
CE
Mark (LVD)
11774-3336-1262
E132002
LR53982C
P95103550
2186
Technical Support: (888) 41-ASTEC or (407) 241-2752
124
Americas: (760) 930-4600
Europe (UK) 44 (1384) 842-211
Asia (HK) 852-2437-9662
rev 12.14.03