LCT43-E Datasheet, PDF (1/2 Pages) Astec America, Inc – 47 Watts
47 Watts
LCT43-E Series
Total Power: 47 Watts
Input Voltage: 85-264 VAC
120-300 VDC
# of Outputs: Triple
Special Features
• Totally enclosed
• Universal input
• Quick Installation
• Built-in EMI filter
• Low output ripple
• Overvoltage protection
• Overload protection
Environmental
Operating temperature: 0° to 50°C ambient;
derate each output at 2.5% per degree from
50° to 70°C
Electromagnetic susceptibility: designed to meet
IEC 1000-4, -2, -3, -4, -5, -6, 8, 11 Level 3
Humidity: Operating; non-condensing
5% to 90%
Vibration: .41 G from 3 to 500 Hz
Spectral break points of .0065 G2/Hz at 10 Hz and
200 Hz and 5 db/octave roll off at each end, 2
hours per axis
Storage temperature: -40° to 85°C
Temperature coefficient: ±.04% per °C
MTBF demonstrated: >300,000 hrs @ full load and
25°C ambient conditions
Electrical Specs
Input
Input range
Frequency
Inrush current
Input current
Efficiency
EMI filter
Safety ground leakage
current
Output
Maximum power
Cross regulation
Hold-up time
Overload protection
Overvoltage protection
85-264 VAC
120-300 VDC
47-63 Hz
<20 A peak @ 115 VAC;
<40 A peak @ 230 VAC,
cold start @ 25°C
1 A max. (RMS) @ 115 VAC
70% typical at full load
FCC Class B conducted and radiated
CISPR 22 Class B conducted and
radiated
EN55022 Class B conducted and
radiated
Bellcore GR-1089-core Class B
conducted
<3.5 mA @ 50/60 Hz, 264 VAC input
47 W with 12 CFM forced air
±2% on output 1;
±5% on outputs 2, 3
10 ms @ 47 W load, 100 VAC input
Short circuit protection on all
outputs.
Case overload protected @ 110-
135% above peak rating
5.50-6.75 VDC on main output
Safety
VDE
0805/EN60950 (IEC950)
21310-3336-0003
UL
UL1950
E186249
CSA
CSA 22.2-234 -950-95-M90
CB
Certificate and report
6593
CE
Mark (LVD)
rev 8.11.04
Technical Support: (888) 41-ASTEC or (407) 241-2752
90
Americas: (760) 930-4600
Europe (UK) 44 (1384) 842-211
Asia (HK) 852-2437-9662