English
Language : 

AEH60F48 Datasheet, PDF (1/21 Pages) Astec America, Inc – Industry Standard Brick - 36-75V Input, 3.3V / 60A Output
Technical Reference Notes
Hercules (AEH/ALH60) Open
Frame or HS Adapted
AEH60F48 /ALH60F48 Isolated DC/DC Converter Module
Industry Standard ½ Brick – 36-75V Input, 3.3V / 60A Output
The AEH60F48 / ALH60F48 is part of Astec’s New Ultra High Density ½ Brick family capable of running 60Amps at 3.3V
output. With Efficiencies up to 92% typical at 3.3V - 60Amps, this product provides a 1% to 2% performance increase in
efficiency over the leading 60Amp competitors and up to 10% higher output current. The operating temperature range (-
40°C to 85°C for the ALH; -40°C to 100°C baseplate for AEH) assures maximum application flexibility. New single-
output models feature superior transient response with excellent stability in high capacitance/low ESR load applications.
This family has an effective thermal adapter plate which allows for heat sinking under particularly harsh conditions.
Without the adapter plate (ALH60) provides a very effective low profile which performs extremely well in convection
cooled applications.
Electrical Parameters
Industry Standard
½ Brick Package
Special Features
•
High efficiency, 92% (30-70%Load))
•
-40°C to 100°C baseplate operating temp
•
Open Frame version also available
(ALH60)
•
Positive and Negative enable function
•
Low output ripple and noise
•
High capacitive load limit
•
Remote sense compensation
•
Regulation to zero load
•
Fixed frequency switching (190 KHz)
Environmental Specifications
•
Operating temperature:
-40°C to +85°C for Open Frame (ALH60)
-40°C to +100°C (Baseplate) for (AEH60)
•
Storage temperature: -40°C to +125C
•
MTBF: >1 million hours
Input
Input range
Input Surge
Efficiency
36-75 VDC
100V / 100ms
91%@3.3V (Typical @ 60
Amps)
Control
Enable
TTL compatible
(Positive & Negative enable options)
Output
Regulation
(Line, Load, Temp) <2%
Ripple and Noise
Remote Sense
2% typical (100mV p-p
max)
Up to 10%Vout
Output Voltage
Adjust Range
±10% of nominal output
Transient Response 150mV max deviation with
50% to 75% full load
300 µS (max) recovery
Over Voltage
Protection
130% nominal
Safety
§ UL, cUL 60950 Recognized
§ EN 60950 through TUV-PS
MODEL: AEH/ALH60F48
SEPTEMBER 26, 2002 - REVISION 02
SHEET 1 OF 21