English
Language : 

PMIS3-20-5-50KHZ Datasheet, PDF (1/9 Pages) ASM GmbH – Magnetic Scale Position Sensor
PMIS3 POSIMAG®
Magnetic Scale Position Sensor
Very compact sensor for industrial applications
Sensor head PMIS3
• Non-contact, no wear
• High velocity
• Robust shielded metal enclosure
• Protection class IP67
• Incremental encoder output A/B/Z
• Signal processing as usual with encoders
• Reference pulse and end position signal
• Indicator for velocity/position errors
A POSIMAG measuring system consists of the
sensor head PMIS3 and the magnetic scale PMIB3
with the same magnetic period.
Specifications
Output
Excitation voltage
Excitation current
Magnetic period of the sensor
Guided spacing between sensor and mag. scale (xz)
Side tracking tolerance of the sensor
Linearity (sensor with mag. scale PMIB3)
Repeatability
Resolution with ext. times 4 counting mode [µm]
Max. velocity with fp=50 kHz [m/s]
(20 kHz: x 0.4; 10 kHz: x 0.2)
Incremental encoder output A/B with differential
push-pull output, TTL/RS422 or HTL compatible
10 ... 30 VDC or 5 VDC ±5 %
50 mA to 300 mA, depending on pulse frequency,
cable length and load
2 mm
5 mm
0.1 ... 0.8 mm
0.1 ... 2 mm
±1 mm
±1 mm
15 µm ± 40 µm/m
30 µm ± 40 µm/m
± 1 digit
± 1 digit
5 10 20 50 10 25 50 125
0.8 1.6 3.2 8 1.6 4 8 20
Order code PMIS3
PMIS3 — — — KHZ— — — M —
Model name
Magnetic period
20 = 2 mm / 50 = 5 mm
Resolution (in µm) with times 4 counting mode
Mag. period 2 mm: 5 / 10 / 20 / 50
Mag. period 5 mm: 10 / 25 / 50 / 125
Max. pulse frequency (in kHz, standard 50 kHz)
50 / 20 / 10
Output
HTL
= HTL output with excitation 24 VDC, output 24 V
TTL
= TTL output with excitation 5 VDC, output TTL/RS422
TTL24V = TTL output with excitation 24 VDC, output TTL/10 mA
Reference pulse/ end position signal/ status signal
Z0
= A/B w/o reference pulse / Z1 = A/B with reference pulse Z
Z2
= A/B with end position signal / *Z3 = A/B with reference pulse
and status signal
(Option Z3 only for non-diferential output, single ended)
Cable length (in m, standard 2 m)
Connection
S
= Cable output, open end
P
= Connector D-sub, 9 pin, at the cable end
6
CAT-PM--E-04
Order example: PMIS3 - 50 - 25 - 50KHZ - HTL - Z1 - 2M - S
Tel.: 08123/986-0 Fax: 08123/986-500 www.asm-sensor.com
ASM GmbH