English
Language : 

3290 Datasheet, PDF (1/4 Pages) ASM GmbH – CLAMP ON AC/DC HiTESTER
3290, 3290-10
CLAMP ON AC/DC HiTESTER
Field Measuring Instruments
Current Measurement at DC and from 1 Hz AC,
with Comprehensive Integrating Functions
Choice of Three Sensors:
20, 200 and 2000 A ranges
Choice of Measurement Modes:
DC, AC+DC, AC and PEAK
Choice of Recording Outputs:
RMS, waveform, frequency and integral value
Choice of Response Times:
switches in three steps
Filter Function:
fc = 550 Hz to suppress undesired harmonics
3290-10 Functions
Independent sensors for convenient portable measuring
* Measurement cable can be up to 100m(328.1ft) long
Current integral measurement
(obtain polarity-specific integrated DC values)
Operating time/duty measurement
100A
φ 35mm
(1.38")
9691 Specifications
200A
● Effect of conductor position: ±1.0% or less
● Effect of external magnetic field:
equivalent to 0.5 A or less
(in 400A/m external magnetic field)
● External dimensions:
approx. 53W(2.09") × 129H(5.08") ×
18D(0.71") mm
● Weight: approx. 230 g(8.1oz)
φ 33mm
(1.3")
9692 Specifications
Protected by dustproof cap!
● Effect of conductor position: ±0.5% or less
● Effect of external magnetic field:
equivalent to 0.7 A or less
(in 400A/m external magnetic field)
● External dimensions:
approx. 62W(2.44") × 167H(6.57") ×
35D(1.38") mm
● Weight: approx. 410 g(14.5oz)
2000A
φ 55mm
(2.17")
9693 Specifications
Sensor Common Specifications
● Effect of conductor position: ±0.7% or less
● Effect of external magnetic field:
equivalent to 2 A or less
(in 400A/m external magnetic field)
● External dimensions:
approx. 62W(2.44") × 196H(7.72") ×
35D(1.38") mm
● Weight: approx. 500 g(17.6oz.)
● Cable length: 2m (6.56 ft) ● Maximum circuit voltage: 600V
● Applicable standards: Safety: EN61010-2-032:1995, CAT III 600V, Pollution Class 2,
EMC: EN61326:1997+A1:1998+A2:2001