English
Language : 

DS-0026 Datasheet, PDF (4/6 Pages) All Sensors Corporation – 1 mbar (0.4 In H2O) to 30 In H2O Pressure Sensors
Performance Characteristics for: 5 INCH-G-4V-MIL
Parameter, NOTE 1
Operating Range, gage pressure
Output Span, NOTE 5
Offset Voltage @ zero pressure
Offset Temperature Shift (-40°C-125°C), NOTE 2
Offset Warm-up Shift, NOTE 3
Offset Position Sensitivity (±1g)
Offset Long Term Drift (one year)
Linearity, hysteresis error, NOTE 4
Span Shift (-40°C-125°C), NOTE 2
Minimum
3.90
0.15
Nominal
5.0
4.0
0.25
±5
±5
±5
0.05
Maximum
4.10
0.35
±40
0.25
±1
Units
“H2O
volt
volt
mvolt
mvolt
mvolt
mvolt
%fs
%span
Performance Characteristics for: 10 INCH-D-4V-MIL
Parameter, NOTE 1
Operating Range, differential pressure
Output Span, NOTE 5
Offset Voltage @ zero differential pressure
Offset Temperature Shift (-40°C-125°C), NOTE 2
Offset Warm-up Shift, NOTE 3
Offset Position Sensitivity (±1g)
Offset Long Term Drift (one year)
Linearity, hysteresis error, NOTE 4
Span Shift (-40°C-125°C), NOTE 2
Minimum
±1.90
2.15
Nominal
±10.0
±2.0
2.25
±5
±5
±5
0.05
Maximum
±2.10
2.35
±20
0.25
±1
Units
“H2O
volt
volt
mvolt
mvolt
mvolt
mvolt
%fs
%span
Performance Characteristics for: 10 INCH-G-4V-MIL
Parameter, NOTE 1
Operating Range, gage pressure
Output Span, NOTE 5
Offset Voltage @ zero pressure
Offset Temperature Shift (-40°C-125°C), NOTE 2
Offset Warm-up Shift, NOTE 3
Offset Position Sensitivity (±1g)
Offset Long Term Drift (one year)
Linearity, hysteresis error, NOTE 4
Span Shift (-40°C-125°C), NOTE 2
Minimum
3.90
0.15
Nominal
10.0
4.0
0.25
±5
±5
±5
0.05
Maximum
4.10
0.35
±20
0.25
±1
Units
“H2O
volt
volt
mvolt
mvolt
mvolt
mvolt
%fs
%span
Amplified Low Pressure Sensors Military Grade