0.3PSI-G-HGRADE-MINI Datasheet, PDF (4/4 Pages) All Sensors Corporation – H-Grade Pressure Sensors
Performance Characteristics for 15 PSI-A-HGRADE-MINI
Parameter, note 1
Minimum
Nominal
Operating Range, absolute pressure
--
15.0
Output Span, note 5
89.1
90.0
Offset Voltage @ zero differential pressure
--
--
Offset Temperature Shift (0°C-70°C), note 2
--
--
Linearity, hysteresis error, note 4
--
0.25
Span Shift (0°C-70°C), note 2
--
--
Maximum
--
90.9
±0.5
±0.5
0.5
±1
Units
PSIA
mV
mV
mV
%fs
%fs
Performance Characteristics for 30 PSI-G-HGRADE-MINI
Parameter, note 1
Minimum
Nominal
Operating Range, gage pressure
--
30.0
Output Span, note 5
89.1
90.0
Offset Voltage @ zero gage pressure
--
--
Offset Temperature Shift (0°C-70°C), note 2
--
--
Linearity, hysteresis error, note 4
--
0.25
Span Shift (0°C-70°C), note 2
--
--
Performance Characteristics for 30 PSI-A-HGRADE-MINI
Parameter, note 1
Minimum
Nominal
Operating Range, absolute pressure
--
30.0
Output Span, note 5
89.1
90.0
Offset Voltage @ zero differential pressure
--
--
Offset Temperature Shift (0°C-70°C), note 2
--
--
Linearity, hysteresis error, note 4
--
0.25
Span Shift (0°C-70°C), note 2
--
--
Performance Characteristics for 100 PSI-G-HGRADE-MINI
Parameter, note 1
Operating Range, gage pressure
Output Span, note 5
Offset Voltage @ zero gage pressure
Offset Temperature Shift (0°C-70°C), note 2
Linearity, hysteresis error, note 4
Span Shift (0°C-70°C), note 2
Minimum
--
99.0
--
--
--
--
Nominal
100.0
100.0
--
--
0.25
--
Specification Notes
Maximum
--
90.9
±0.5
±0.5
0.5
±1
Maximum
--
90.9
±0.5
±0.5
0.5
±1
Maximum
--
101.0
±0.5
±0.5
0.5
±1
Units
PSI
mV
mV
mV
%fs
%fs
Units
PSIA
mV
mV
mV
%fs
%fs
Units
PSI
mV
mV
mV
%fs
%fs
note 1: All parameters are measured at 12.0 volt excitation, for the nominal full scale pressure and room temperature unless
otherwise specified. Pressure measurements are with positive pressure applied to Port B.
note 2: Shift is relative to 25°C.
note 3: Shift is within the first hour of excitation applied to the device.
note 4: Measured at one-half full scale rated pressure using best straight line curve fit.
note 5: The voltage added to the offset voltage at full scale pressure.
Pressure Response: for any pressure applied the response time to get to 90% of pressure applied is typically less
than 100 useconds.
All Sensors reserves the right to make changes to any products herein. All Sensors does not assume any liability arising out of the application or use of any product or
circuit described herein, neither does it convey any license under its patent rights nor the rights of others.
Miniature H-grade Pressure Sensors