DS-02743 Datasheet, PDF (3/16 Pages) All Sensors Corporation – MLV Series Low Voltage Pressure Sensors | |||
|
◁ |
Performance Characteristics for MLV Series (PSI)
All parameters are measured at 5.0 volt excitation and room temperature unless otherwise specified. Pressure measurements are with positive pressure applied
to PORT B (the only port for the single port configuration packages). Pressure is applied to Port A for absolute devices in A-Package.
Parameter
Min
Typ
Max Units Notes
Output Span
005D @ 5 PSI
24.75
25.0
25.25
mV
4
015D @ 15 PSI
37.13
37.50
37.88
mV
4
015A @ 15 PSIA
37.13
37.50
37.88
mV
4
030D @ 30 PSI
37.13
37.50
37.88
mV
4
100D @ 100 PSI
41.25
41.67
42.08
mV
4
150D @ 150 PSI
37.08
37.50
37.92
mV
4
Span Temperature Shift (0°C to 50°C)
-
-
±1.0
%FSS
1
Offset Voltage @ Zero Diff. Pressure
005D @ 5 PSI
015D @ 15 PSI
015A @ 15 PSIA
030D @ 30 PSI
100D @ 100 PSI
150D @ 150 PSI
-
-
125
uV
-
-
-
125
uV
-
-
-
208
uV
-
-
-
125
uV
-
-
-
125
uV
-
-
-
125
uV
-
Offset Warm-Up Shift
-
±20
uV
2
Offset Long Term Drift (one year)
-
±100
-
uV
-
Linearity, Hysteresis Error
-
0.20
0.50
%FSS
3
Response Time (10% to 90% Pressure Response)
-
500
-
us
-
Front to Back Linearity
-
2.5
-
%FSS
5
Input Resistance
-
12.0
-
k ohm
-
Output Resistance
-
3.0
-
k ohm
-
Specification Notes
note 1: Shift is relative to 25°C.
note 2: Shift is within the first hour of excitation applied to the device.
note 3: Measured at one-half full scale rated pressure using best straight line curve fit.
note 4: The span is the algebraic difference between full scale output voltage and the offset voltage.
note 5: Front-Back Linerity computed as: Lin FB


Span Front

â 1 â
100%
ï£ Span Back 
note 6: Parameter is characterized and not 100% tested.
All Sensors
DS-0274 Rev C
|
▷ |