Performance Characteristics for 2 INCH-Dx-MV-MINI
Parameter, note 1
Operating Range, differential pressure
Output Span, @ 2 “H2O, note 5
Operating Range, differential pressure
Output Span, @ 4 “H2O, note 5
Offset Voltage @ zero differential pressure
Offset Temperature Shift (0°C-50°C), note 2
Offset Warm-up Shift, note 3
Offset Position Sensitivity (1g)
Offset Long Term Drift (one year)
Linearity, hysteresis error, note 4
Span Shift (0°C-50°C), @ 2 “H2O, note 2
Minimum
9.0
18.0
Nominal
2.0
10.0
4.0
20.0
0.05
Performance Characteristics for 5 INCH-Dx-MV-MINI
Parameter, note 1
Operating Range, differential pressure
Output Span, note 5
Offset Voltage @ zero differential pressure
Offset Temperature Shift (0°C-50°C), note 2
Offset Warm-up Shift, note 3
Offset Position Sensitivity (1g)
Offset Long Term Drift (one year)
Linearity, hysteresis error, note 4
Span Shift (0°C-50°C), note 2
Minimum
19.0
Nominal
5.0
20.0
0.05
Maximum
11.0
22.0
±500
±250
±100
±50
±200
0.25
±200
Maximum
21.0
±500
±150
±50
±10
±100
0.25
±200
Performance Characteristics for 10 INCH-Dx-MV-MINI
Parameter, note 1
Operating Range, differential pressure
Output Span, note 5
Offset Voltage @ zero differential pressure
Offset Temperature Shift (0°C-70°C), note 2
Offset Warm-up Shift, note 3
Offset Position Sensitivity (1g)
Offset Long Term Drift (one year)
Linearity, hysteresis error, note 4
Span Shift (0°C-70°C), note 2
Minimum
19.0
Nominal
10.0
20.0
0.05
Maximum
21.0
±500
±150
±50
±5
±100
0.25
±200
All Sensors
DS-0108 Rev A
Units
“H2O
mV
mV
mV
uV
uV
uV
uV
uV
%fs
uV
Units
“H2O
mV
uV
uV
uV
uV
uV
%fs
uV
Units
“H2O
mV
uV
uV
uV
uV
uV
%fs
uV