English
Language : 

DS-0102 Datasheet, PDF (3/6 Pages) All Sensors Corporation – MiniatureAmplifiedLowPressureSensors
Performance Characteristics for 1 INCH-Dx-P4V-MINI
Parameter, note 1
Operating Range, differential pressure
Output Span, note 5
Offset Voltage @ zero differential pressure
Offset Temperature Shift (-25°C-85°C), note 2
Offset Warm-up Shift, note 3
Offset Position Sensitivity (±1g)
Offset Long Term Drift (one year)
Linearity, hysteresis error, note 4
Span Shift (-25°C-85°C), note 2
Minimum
±1.90
2.15
Nominal
±1.0
±2.0
2.25
±10
±5
±10
0.05
Maximum
±2.10
2.35
±60
0.25
±2
Units
“H2O
volt
volt
mvolt
mvolt
mvolt
mvolt
%fs
%span
Performance Characteristics for 1 INCH-G-P4V-MINI
Parameter, note 1
Operating Range, gage pressure
Output Span, note 5
Offset Voltage @ zero pressure
Offset Temperature Shift (-25°C-85°C), note 2
Offset Warm-up Shift, note 3
Offset Position Sensitivity (±1g)
Offset Long Term Drift (one year)
Linearity, hysteresis error, note 4
Span Shift (5°C-50°C), note 2
Minimum
3.90
0.15
Nominal
1.0
4.0
0.25
±10
±15
±10
0.05
Maximum
4.10
0.35
±60
0.25
±2
Units
“H2O
volt
volt
mvolt
mvolt
mvolt
mvolt
%fs
%span
Performance Characteristics for 5 INCH-Dx-P4V-MINI
Parameter, note 1
Operating Range, differential pressure
Output Span, note 5
Offset Voltage @ zero differential pressure
Offset Temperature Shift (-25°C-85°C), note 2
Offset Warm-up Shift, note 3
Offset Position Sensitivity (±1g)
Offset Long Term Drift (one year)
Linearity, hysteresis error, note 4
Span Shift (-25°C-85°C), note 2
Minimum
±1.90
2.15
Nominal
±5.0
±2.0
2.25
±5
±5
±5
0.05
Maximum
±2.10
2.35
±40
0.25
±1
Units
“H2O
volt
volt
mvolt
mvolt
mvolt
mvolt
%fs
%span
All Sensors
DS-0102 Rev A