English
Language : 

DS-0040 Datasheet, PDF (3/3 Pages) All Sensors Corporation – 600 to 1,100 mbar Barometric Pressure Sensor
Performance Characteristics for BARO-A-4V-MINI
Parameter, note 1
Operating Range, absolute pressure
Output Voltage @1,100 mbar
Output Voltage @ 600 mbar
Offset Temperature Shift (5°C to 50°C), note 2
Linearity, hysteresis error, note 4
Span Shift (5°C to 50°C), note 2
Minimum
600
4.15
0.15
Nominal
4.25
0.25
0.05
Maximum
1100
4.35
0.35
±20
0.50
±1
Performance Characteristics for BARO-A-4V-MINI-PRIME
Parameter, note 1
Operating Range, absolute pressure
Output Voltage @1,100 mbar
Output Voltage @ 600 mbar
Offset Temperature Shift (-25°C to 85°C), note 2
Linearity, hysteresis error, note 4
Span Shift (-25°C to 85°C), note 2
Minimum
600
4.15
0.15
Nominal
4.25
0.25
0.05
Maximum
1100
4.35
0.35
±20
0.50
±1
Units
mBar
volt
volt
mvolt
%fs
%span
Units
mBar
volt
volt
mvolt
%fs
%span
Performance Characteristics for BARO-A-4V-MINI-MIL
Parameter, note 1
Operating Range, absolute pressure
Output Voltage @1,100 mbar
Output Voltage @ 600 mbar
Offset Temperature Shift (-40°C to 125°C), note 2
Linearity, hysteresis error, note 4
Span Shift (-40°C to 125°C), note
Minimum
600
4.15
0.15
Nominal
4.25
0.25
0.05
Maximum
1100
4.35
0.35
±20
0.50
±1
Units
mBar
volt
volt
mvolt
%fs
%span
Specification Notes
NOTE 1: ALL PARAMETERS ARE MEASURED AT 5.0 VOLT EXCITATION, FOR THE NOMINAL FULL SCALE PRESSURE AND ROOM TEMPERATURE UNLESS
OTHERWISE SPECIFIED. PRESSURE MEASUREMENTS ARE WITH POSITIVE PRESSURE APPLIED TO THE B-PORT.
NOTE 2: SHIFT IS RELATIVE TO 25°C.
NOTE 3: MEASURED AT ONE-HALF FULL SCALE RATED PRESSURE USING BEST STRAIGHT LINE CURVE FIT.
All Sensors reserves the right to make changes to any products herein. All Sensors does not assume any liability arising out of the application or
use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others.
all sensors
DS-0040 Rev C