English
Language : 

DS-0010 Datasheet, PDF (3/5 Pages) All Sensors Corporation – Enhanced Digital Output Sensors: Industrial temperature range
Synchronous Timing Diagram (Note: Asynchronous mode timing is per RS-232. To use RS-232 requires the Maxim MA232
interface circuit for proper voltage level compatibility.)
READY [Output]
t1
t10
t2
t2
CONVERT [Input]
t3
t4
t8
t9
t5
CLOCK [Output]
t6
t7
DATA [Output]
Ref
Parameter
t1 Conversion Time
t2 Ready to Convert
t3 Convert to Clock
t4 Clock Period
t5 Clock High Time
Bit Bit Bit Bit Bit Bit Bit Bit
15 14 13 12 11 10 9 8
MSB
Bit Bit Bit Bit Bit Bit Bit Bit
76543210
LSB
Min Typ Max Units
--
8
16 msec
0
--
-- usec
24 32 39 usec
-- 24 -- usec
-- 12 -- usec
Ref
Parameter
t6 Data Setup Time
t7 Data Hold Time
t8 Interbyte Delay
t9 Clock to Ready
t10 Data Transmission
Min Typ Max Units
--
3
-- usec
--
3
-- usec
-- 70 -- usec
-- 14 -- usec
-- 476 -- usec
Typical Configurations
Synchronous Communications
Typical synchronous communications
configuration (compatible with All Sensors
GA142 Series Digital Output Sensors).
Host
System
Sensor
Clock/SO
Data/SI
Convert/BR
Ready/Mode
Asynchronous Communications
Typical asynchronous communications
configuration. The Mode pin is interrogated
at power up and if tied low, will cause the
sensor to enter asynchronous communica-
tions mode. This mode supports multiple
sensors by addressable commands. The
Convert/BR pin then serves to select one of
two available baud rates.
Host
System
Sensor (1)
Clock/SO
Data/SI
Convert/BR
Ready/Mode
Sensor (n)
Clock/SO
Data/SI
Convert/BR
Ready/Mode
All Sensors
DS-0010 Rev A