English
Language : 

1INCH-D1-BASIC Datasheet, PDF (3/3 Pages) All Sensors Corporation – Miniature Basic Pressure Sensors
Performance Characteristics for 10 INCH-x-BASIC
Parameter, note 1
Operating Range, differential pressure
Output Span, @ 10 “H2O, note 5
Offset Voltage @ zero differential pressure
Offset Temperature Shift (0°C-70°C), note 2
Offset Warm-up Shift, note 3
Offset Position Sensitivity (1g)
Offset Long Term Drift (one year)
Linearity, hysteresis error, note 4
Minimum
--
15
--
--
--
--
--
--
Performance Characteristics for 20 INCH-x-BASIC
Nominal
10.0
30
--
±0.1
±10
±10
±80
0.1
Maximum
--
45
±10
--
--
---
--
±0.5
Units
“H2O
mV
mV
mV
uV
uV
uV
%fs
Parameter, note 1
Operating Range, differential pressure
Output Span, @ 20 “H2O, note 5
Offset Voltage @ zero differential pressure
Offset Temperature Shift (0°C-70°C), note 2
Offset Warm-up Shift, note 3
Offset Position Sensitivity (1g)
Offset Long Term Drift (one year)
Linearity, hysteresis error, note 4
Minimum
--
15
--
--
--
--
--
--
Nominal
20.0
30
--
±0.1
±10
±5
±80
0.1
Performance Characteristics for 30 INCH-x-BASIC
Maximum
--
45
±10
--
--
--
--
±0.5
Units
“H2O
mV
mV
mV
uV
uV
uV
%fs
Parameter, note 1
Minimum
Nominal
Maximum
Units
Operating Range, differential pressure
--
30.0
--
“H2O
Output Span, @ 30 “H2O, note 5
15
30
45
mV
Offset Voltage @ zero differential pressure
--
--
±10
mV
Offset Temperature Shift (0°C-70°C), note 2
--
±0.1
--
mV
Offset Warm-up Shift, note 3
--
±10
---
uV
Offset Position Sensitivity (1g)
--
±5
---
uV
Offset Long Term Drift (one year)
--
±80
--
uV
Linearity, hysteresis error, note 4
--
0.05
±0.5
%fs
Specification Notes
note 1: All parameters are measured at 4.5 volt excitation, for the nominal full scale pressure and room temperature unless
otherwise specified. Pressure measurements are with negative pressure applied to the TOP-PORT (the only port for the
single port) configuration.
note 2: Shift is relative to 25°C.
note 3: Shift is within the first hour of excitation applied to the device.
note 4: Measured at one-half full scale rated pressure using best straight line curve fit.
note 5: The voltage added to the offset voltage at full scale pressure.
Pressure Response: for any pressure applied the response time to get to 90% of pressure applied is typically less
than 100 useconds.
All Sensors reserves the right to make changes to any products herein. All Sensors does not assume any liability arising out of the application or use of
any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others.
All Sensors
DS-0105 Rev B