English
Language : 

DS-0025 Datasheet, PDF (2/6 Pages) All Sensors Corporation – 1 mbar (0.4 In H2O) to 30 In H2O Pressure Sensors
Pressure Sensor Ratings
Supply Supply Voltage VS
Common-mode pressure
Lead Temperature, max
(soldering 2-4 sec.)
+4.5 to +5.5 Vdc
-10 to +10 psig
250°C
Environmental Specifications
Temperature Ranges
Compensated
Operating
Storage
Humidity Limits
-25 to 85° C
-40 to 125° C
-40 to 125° C
0 to 95% RH
(non condensing)
Standard Pressure Ranges
Part Number
1 MBAR-D-4V-PRIME
1 INCH-D-4V-PRIME
1 INCH-G-4V-PRIME
5 INCH-D-4V-PRIME
5 INCH-G-4V-PRIME
10 INCH-D-4V-PRIME
10 INCH-G-4V-PRIME
20 INCH-D-4V-PRIME
20 INCH-G-4V-PRIME
30 INCH-D-4V-PRIME
30 INCH-G-4V-PRIME
Operating Pressure
±1 mbar
±1 In H2O
0 - 1 In H2O
± 5 In H2O
0 - 5 In H2O
±10 In H2O
0 - 10 In H2O
±20 In H2O
0 - 20 In H2O
±30 In H2O
0 - 30 In H2O
Nominal Span
4V
4V
4V
4V
4V
4V
4V
4V
4V
4V
4V
Proof Pressure
100 In H2O
100 In H2O
100 In H2O
200 In H2O
200 In H2O
200 In H2O
200 In H2O
300 In H2O
300 In H2O
500 In H2O
500 In H2O
Burst Pressure
200 In H2O
200 In H2O
200 In H2O
300 In H2O
300 In H2O
300 In H2O
300 In H2O
500 In H2O
500 In H2O
800 In H2O
800 In H2O
Performance Characteristics for: 1 MBAR-D-4V-PRIME
Parameter, NOTE 1
Operating Range, differential pressure
Output Span, NOTE 5
Offset Voltage @ zero differential pressure
Offset Temperature Shift (-25°C to 85°C), NOTE 2
Offset Warm-up Shift, NOTE 3
Offset Position Sensitivity (±1g)
Offset Long Term Drift (one year)
Linearity, hysteresis error, NOTE 4
Span Shift (-25°C to 85°C), NOTE 2
Minimum
--
±1.80
2.00
--
--
--
--
--
--
Nominal
±1.0
±2.0
2.25
--
±20.0
±40.0
±20.0
0.05
--
Maximum
--
±2.20
2.50
±120
--
--
--
0.25
±4.0
Units
mbar
volt
volt
mvolt
mvolt
mvolt
mvolt
%fs
%span