English
Language : 

DS-0032 Datasheet, PDF (1/3 Pages) All Sensors Corporation – AMPLIFIED Pressure Sensors
Amplified Very Low Pressure Sensors
AMPLIFIED Pressure Sensors
Features
• 0.25 and 0.50 In H2O Pressure Ranges
• Ratiometric 4V Output
• Temperature Compensated
• Calibrated Zero and Span
General Description
Applications
• Medical Breathing
• HVAC
The Amplified line of low pressure sensor is based upon a proprietary technology to reduce all output offset or common mode errors.
This model provides a ratiometric 4-volt output with superior output offset characteristics. Output offset errors due to change in
temperature, stability to warm-up, stability to long time period, and position sensitivity are all significantly reduced when compared to
conventional compensation methods. In addition the sensor utilizes a silicon, micromachined, stress concentration enhanced structure
to provide a very linear output to measured pressure.
These calibrated and temperature compensated sensors give an accurate and stable output over a wide temperature range. This series
is intended for use with non-corrosive, non-ionic working fluids such as air, dry gases and the like.
The output of the device is ratiometric to the supply voltage over a supply voltage range of 4.5 to 5.5 volts.
Physical Dimensions
Equivalent Circuit
8.74
0.344
2.54
0.100
(Typ)
CL 1.27
0.050
0.020" x 0.010" Pin
0.30" minimum length
Port 0.179"/0.189" Pin 1 Identifier
-
Port A
+
12.19
0.480
13.97
0.550
3.56
0.140
3.18
R0.125
Port B
20.32
0.800
21.59
0.850
pin 1: Vsupply
pin 2: Common
pin 3: Voutput
pin 4: do not connect
Vs
Vout
Gnd
All Sensors
DS-0032 Rev B