DS500SPE-3 Datasheet, PDF (4/7 Pages) Artesyn Technologies – 500 Watts Distributed Power System
DS500SPE Data Sheet
Electrical Specifications
LED Indicators
A single bi-color LED is used to indicate the power supply status.
No AC input to PSU
Main output ON
Standby mode or Power supply failure (OCP, OVP, OTP, FAN FAULT)
Status LED
Off
Solid GREEN
Blinking AMBER
Firmware Reporting And Monitoring
Output loading
Input voltage
Input current
Input power
Output voltage
Output current
Temperature
EIN
Fan speed
5 to 20%
±0.55 A fixed error
±6.25 W at <125 W input
1.5 A fixed error
±15% from 10% to 20% load
PMBus
YES
Remote ON/OFF
YES
Accuracy Range
20 to 50%
±5%
±4%
±5%
±2%
±3%
±5 °C on the operating range
±5%
Actual RPM ±250 RPM
50 to 100%
Timing Specifications
Description
Min
Max
Unit
Tsb_On
Delay from AC being applied to standby output being within regulation
20
2000
ms
Tsb_ACOK
Delay from standby output to ACOK assertion
See note below
20
ms
Tsb_Vout
Delay from standby output to main output voltage being within regulation
300
ms
TAC_On_Delay
Delay from AC being applied to main output being within regulation
2300
ms
TPWR_GOOD_On
Delay from output voltages within regulation limits to PWOK asserted
100
1000
ms
TACOK_Delay
Delay from loss of AC to assertion of ACOK
7
ms
TPWR_GOOD_Hold-up
Delay from loss of AC to deassertion of PWOK
10
ms
TVout_Hold-up
Delay from loss of AC to main output being within regulation
11
ms
Tsb_Hold-up
Delay from loss of AC to standby output being within regulation
150
ms
TPWR_GOOD_Off
Delay from deassertion of PWOK to output falling out of regulation
1
ms
TPSON_On_Delay
Delay from PSON assertion to output being within regulation
350
ms
TPWOK_Low
Duration of PWOK being in deasserted state during an ON/OFF cycle of PSU
N/A
N/A
Note: T : vout_hold-up tested at 1A load on standby output
Tsb_ACOK: ACOK can assert earlier than the standby output