English
Language : 

NPS42-M Datasheet, PDF (3/3 Pages) Emerson Network Power – Embedded Power for Business-Critical Continuity
NPS40-M Series Data Sheet
Ordering Information
Model Number
Output Voltage
Minimum
Load
Maximum Load with
Convection Cooling
NPS42-M
5V
0A
8A
NPS43-M
12 V
0A
3.75 A
NPS44-M
15 V
0A
3A
NPS45-M
24 V
0A
1.9 A
NPS48-M
48 V
0A
0.94 A
Maximum Load with
200LFM Forced Air
11 A
5A
4A
2.5 A
1.25 A
Peak Load1 Regulation2
13 A
5.5 A
4.4 A
2.75 A
1.38 A
± 2%
± 2%
± 2%
± 2%
± 2%
Ripple
P/P (PARD)3
50 mV
120 mV
150 mV
240 mV
480 mV
1. Peak current lasting < 15 seconds with a maximum 10% duty cycle.
2­. At 25 °C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings.
3­. Peak-to-peak with 20 MHz bandwidth and 10 µF (tantalum capacitor) in parallel with a 0.1 µF capacitor at rated line voltage and load ranges.
4. This product is a Component Power Supply and is only for inclusion by professional installers within other equipment and must not be operated as
a standalone product. EMC compliance to appropriate standards must be verified at the system level. This product is for sale to OEMs and System
Integrators, including through Distribution Channels. It is not intended for sale to End Users.
Pin Assignments
Connector
NPS42-M
SK1-1
Line
SK1-3
Neutral
CN1
Ground
SK2-1
+5 V
SK2-2
+5 V
SK2-3
Common
SK2-4
Common
SK2-5
-Sense
SK2-6
+Sense
NPS43-M
Line
Neutral
Ground
+12 V
+12 V
Common
Common
-Sense
+Sense
NPS44-M
Line
Neutral
Ground
+15 V
+15 V
Common
Common
-Sense
+Sense
NPS45-M
Line
Neutral
Ground
+24 V
+24 V
Common
Common
-Sense
+Sense
NPS48-M
Line
Neutral
Ground
+48 V
+48 V
Common
Common
-Sense
+Sense
Mating­ Connectors
AC Input
Molex 09-50-8031 (USA)
09-91-0300 (UK)
PINS: 08-52-0113
DC Outputs
Molex 09-50-8061 (USA)
09-93-0600 (UK)
PINS: 08-52-0113
Artesyn Embedded Technologies Connector Kit #70-841-006, includes
all of the above
Notes:
1. Specifications subject to change without notice.
2. All dimensions in inches (mm), tolerance is ±0.02”­­(±0.5mm)
3. Mounting holes M1 and M2 should be grounded for EMI
purposes.
4. Mounting hole M1 is safety ground connection.
5. Specifications are for convection rating at factory settings at 115
VAC input, 25 °C unless otherwise stated.
6. For DC input an external DC safety rated fuse must be used
7. Warranty: 2 year
8. Weight: 0.26lbs/0.118kg
Americas
2900 S.Diablo Way
Tempe, AZ 85282
USA
+1 888 412 7832
WORLDWIDE OFFICES
Europe (UK)
Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX
United Kingdom
+44 (0) 1384 842 211
Asia (HK)
14/F, Lu Plaza
2 Wing Yip Street
Kwun Tong, Kowloon
Hong Kong
+852 2176 3333
Artesyn Embedded Technologies, Artesyn and the Artesyn Embedded Technologies logo are trademarks and
service marks of Artesyn Embedded Technologies, Inc. All other names and logos referred to are trade names,
trademarks, or registered trademarks of their respective owners. © 2016 Artesyn Embedded Technologies, Inc.
All rights reserved. For full legal terms and conditions, please visit www.artesyn.com/legal.
www.artesyn.com
For more information: www.artesyn.com/power
For support: productsupport.ep@artesyn.com
NPS40-M DS 21Mar2016