NFS110-7601PJ Datasheet, PDF (3/5 Pages) Emerson Network Power – Single & quad output
Embedded Power for
Business-Critical Continuity
Ordering Information
Output
Voltage
Max (1)
+5.1 V
8A
+12 V
4.5 A
–12 V
0.5 A
–5 V
0.5 A
+5.1 V (IA)
+24 V (IB) (6)
+12 V
8A
3.5 A
4.5 A
–12 V
0.5 A
+5.1 V
8A
15 V
4A
-15 V
0.5 A
-5 V
0.5 A
12 V
7A
15 V
5A
24 V
3.5 A
Output Currents
Peak (2)
20 A
9A
1.5 A
1.5 A
20 A
4.5 A
9A
1.5 A
20 A
7.5 A
1.5 A
1.5 A
9A
7.3 A
4.5 A
Fan (3)
10 A
5A
1A
1A
10 A
4.5 A
5A
1A
10 A
5A
1A
1A
9A
7.3 A
4.5 A
Rev. 11.2.09_69
NFS110 Series
3 of 5
Ripple (4)
50 mV
120 mV
120 mV
50 mV
50 mV
240 mV
120 mV
120 mV
50 mV
150 mV
150 mV
50 mV
120 mV
150 mV
240 mV
Total
Regulation (5)
± 2.0%
± 3.0%
± 3.0%
± 3.0%
± 2.0%
+10/–5.0%
± 3.0%
± 3.0%
± 2.0%
± 4.0%
± 3.0%
± 3.0%
± 2.0%
± 2.0%
± 2.0%
Model Numbers (13, 15, F)
NFS110-7601PJ (14)
NFS110-7602PJ (6, 14)
NFS110-7604PJ (14)
NFS110-7612J (7,8)
NFS110-7615J (7,8)
NFS110-7624J (7,8)
Notes
1 Convection cooled, 80 W maximum.
2 Peak outputs lasting less than 60 seconds with duty cycle less than 10%. Total
peak power must not exceed 110 W.
3 Forced air, 20 CFM at 1 atmosphere, 110 W maximum.
4 Figure is peak-to-peak. Output ripple is measured across a 50 MHz bandwidth
using a 12 inch twisted pair terminated with a 47 µF capacitor.
5 Total regulation is defined as the static output regulation at 25 °C, including
initial tolerance, line voltage within stated limits and output voltages adjusted
to their factory settings.
6 To achieve stated regulation on the 24 V output on the NFS110-7602PJ, the
following load condition must be true: IA / IB ≤ 5, where:
IA = +5.1 V output current, and
IB = +24 V output current
The +24 V output will maintain ±5.0% regulation under the following
additional condition: IA ≤ 5 A.
7 Single output models have floating outputs which may be referenced as
either positive or negative. Higher voltage supplies may be adjusted over a
wide output voltage range, as long as the total output power does not exceed
80 Watts (natural convection) or 110 Watts (forced air).
8 Power fail detect not available on single output models.
9 Derating curve is application specific for ambient temperatures >50 °C,
for optimum reliability no part of the heatsink should exceed 90 ºC and no
semiconductor case temperature should exceed 100 ºC.
10 Caution: Allow a minimum of 1 second after disconnecting the power when
making thermal measurements.
11 Three orthogonal axes, random vibration, 10 minute test for each axis.
12 This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
13 Recommend a minimum load of 11 W to achieve the design MTBF. See the
derating curve on page 4.
14 Power failure detec is optional by including the suffix “P” to the model
number.
15 The ‘J’ suffix indicates that these parts are Pb-free (RoHS 6/6) compliant.
16 NOTICE: Some models do not support all options. Please contact your
local Emerson Network Power representative or use the on-line model
number search tool at http://www.PowerConversion.com to find a suitable
alternative.
Transient Response
NFS110-7601PJ +5.1 V (7.5 A to 10 A)
+12 V (2.5 A to 5 A)
-12 V (0.5 A to 1 A)
-5 V (0.5 A to 1 A)
NFS110-7602PJ
+5.1 V (7.5 A to 10 A)
+24 V (1.5 A to 3 A)
+12 V (2.5 A to 5 A)
-12 V (0.5 A to 1 A)
NFS110-7604PJ
+5.1 V (7.5 A to 10 A)
+15 V (2.5 A to 5 A)
-15 V (0.5 A to 1 A)
-5 V (0.5 A to 1 A)
NFS110-7605J +5.1 V (10 A to 20 A)
NFS110-7612J: +12 V (4.5 A to 9 A)
NFS110-7615J +15 V (3.65 A to 7.3 A)
NFS110-7624J +24 V (2.25 A to 4.5 A)
150 mV peak, 1 ms recovery
100 mV peak, 0.5 ms recovery
100 mV peak, 0.5 ms recovery
100 mV peak, 0.5 ms recovery
150 mV peak, 1 ms recovery
300 mV peak, 1 ms recovery
100 mV peak, 0.5 ms recovery
100 mV peak, 0.5 ms recovery
150 mV peak, 1 ms recovery
100 mV peak, 0.5 ms recovery
100 mV peak, 0.5 ms recovery
100 mV peak, 0.5 ms recovery
250 mV peak, 1 ms recovery
360 mV peak, 1 ms recovery
450 mV peak, 1 ms recovery
720 mV peak, 1 ms recovery