English
Language : 

NLP65-7608G Datasheet, PDF (2/4 Pages) Artesyn Technologies – Universal Input, Low profile fits 1U applications, Overvoltage and short circuit protection
Embedded Power for
Business-Critical Continuity
All specifications are typical at nominal input, full load at 25° C unless otherwise stated.
EMC Charateristics (11, 12)
Conducted emissions:
ESD  air:
EN55022, FCC part 15
EN61000-4-2, level 3
ESD contact:
Surge:
Fast transients:
Radiated immunity:
Conducted immunity:
EN61000-4-2, level 4
EN61000-4-2, level 3
EN61000-4-4, level 3
EN61000-4-3, level 3
EN61000-4-6, level 3
General Specifications
Hold-up time:
120 Vac, 60 Hz
230 Vac, 50 Hz
Efficiency:
120 Vac, 65 W
Isolation voltage:
Input/output
Input/chassis
Switching frequency:
Fixed
Approvals and standards: (see EN60950, VDE0805
Notes 9, 13)
IEC950, UL1950, CCC60950
CSA C22.2 No. 950
Weight:
283 g (10 oz)
MTBF demonstrated:
MIL-HDBK-217F
Level B
Perf. criteria 1
Perf. criteria 1
Perf. criteria 1
Perf. criteria 1
Perf. criteria 2
Perf. criteria 2
16 ms @ 65 W
78 ms @ 65 W
72% typical
3000 Vac
1500 Vac
100 kHz, ±5 kHz
150,000 hours min
Rev.12.12.08_102
NLP65 Series
 of 4
Environmental Specifications
Thermal performance:
(See notes 1, 3, 10)
Relative humidity:
Altitude:
Vibration (See Note 5):
Shock
Operating
(See derating curve)
0° C to +70 °C
Non-operating
-40 °C to +85 °C
50 °C - 70 °C ambient,
convection cooled
Derate to 50% load
0 °C to 50 °C, ambient,
convection cooled
65 W
0 °C to 50 °C, ambient
75 W
20CFM forced air (See Note 10)
Peak (0 °C to 50 °C, 60 s)
See table
Non-condensing
5 to 95% RH
Operating
10,000 feet max.
Non-operating
30,000 feet max.
5-500 Hz
2.4 G rms peak
per MIL-STD-810E
516.4 Part IV
DERATING CURVE
Output Power (Watts)
75W
20 CFM FORCED AIR COOLING
65W
NATURAL
CONVECTION
COOLING
38W
32W