English
Language : 

LPT100-M Datasheet, PDF (2/4 Pages) Emerson Network Power – 130 Watts Medical and ITE safeties
LPT100-M Series Data Sheet
Environmental Specifications
Operating temperature
0 °C to 50 °C ambient derate each output as 2.5% per degree from 50 °C to 70 °C. -20 °C start up
Storage temperature
-40 °C to +85 °C
Electromagnetic susceptibility: Designed to meet EN61000-4; -2, -3, -4, -5, -6, -8, -11 Level 3
Humidity
Operating; non-condensing 10% to 90% RH, non-operating, non-condensing 10% - 95%
Vibration
IEC68-2-6 to the levels of IEC721-3-2
MTBF calculated
583,000 hours at full load and 25 °C ambient conditions. 230 Vac input, Bellcore
Mechanical Drawing
ADJUST POT'S
OUTPUT VOLTAGE
SK3
SEE DETAIL A
GND
PIN 1 (LIVE)
SK1
PIN 3 (NEUTRAL)
1
SK2
8
0.16
[4]
4 places mounting hole
max screw head
diameter 0.22"[5.6]
3.72 "
[94,6]
4"
[101,6]
1
POWER FAIL
COMMON
(+) REMOTE SENSE
(-) REMOTE SENSE
4
SK3
DETAIL A