Electrical Specifications
Output
Output rating
Standby output
Set point
Total regulation
Rated load
Minimum load
Output voltage adjust range
Output noise
Remote sense
Over current protection
Over voltage protection
Over temperature protection
AC_OK
DC_OK
Remote inhibit
# Units in parallel operation
Output dimming
See Ordering Information table
5.0 Vdc @ 1.5 A Max
± 0.5%
Main Output: ± 2.0%
5 Vsb: ± 5%
600 W maximum
0A
See Ordering Information table
Main Output: 1.0% max p-p
5 Vsb: 60 mV max p-p
Compensation up to 500 mV
105 - 130% of full load current
125 - 145% Vo, nom Main Output
125 - 130% 5 Vsb
> 95 °C Baseplate temperature
Open Collector; 0.8 Vdc max / 10 mA
Open Collector; 0.8 Vdc max / 10 mA
Contact Closure
Qualified up to 5 units in parallel. Consult factory if
more than 5 are required.
0-10 Vdc external voltage;
0-100 kOhm external resistance
Factory set point
Combined Line / Load / Temperature
600 W from -40 °C to 85 °C Baseplate Temp. Derate output
to 28 W @ 95 °C Baseplate Temp
For both Main and 5 Vsb Outputs
Max power limited to 600 W
Measured with 0.1 μF Ceramic and 10 μF Tantalum Cap,
20 MHz BW
Pin 10: +Vout_RS / Pin4: -Vout_RS
Default is Shutdown mode with Auto-retry every 2~4 sec.
Output latches after 20 sec of continuous OCP fault
presence. Restart after latch possible through AC recycle,
Inhibit toggle or through PMBus.
Latching / AC Recyle or Inhibit toggle required for PSU
restart
Output Shutdown / Auto-recovery
Active low when AC is present
Active low when Main Output is within regulation
Pin 19: Open/Float = ON; Close/Ground = OFF
Pin 5: IShare pin for main output only.
Consult with productsupport.ep@artesyn.com
Environmental Specifications
Operating temperature range
-40 °C to +85 °C Baseplate temperature
Storage temperature
-40 °C to +85 °C
Humidity
10% to 95%
Altitude
16,402 ft (Operating) / 50,000 ft (Non-Operating)
Shock
MIL-STD-810F 516.5 Procedure I, VI
Vibration
MIL-STD-810F 514.5 Cat. 4, 10
Ingress protection
IP65 (for suffix “-4P”)
MTBF (calculated)
>2M Hrs, 25 °C per SR-332 Issue 3
Electromagnetic immunity
Designed to meet EN61000-4-3, -4, -5, -8, -11 (Level 3); EN61000-4-2 (Level 4); EN60601-1-2 and EN55024
For H suffix, Level 4 for EN61000-4-5