English
Language : 

EXB50-48D3V3-1V8J Datasheet, PDF (2/2 Pages) Artesyn Technologies – 50 W High Efficiency DC-DC Converters
EXB50 Dual Series
Dual positive output
DC-DC CONVERTERS 50 W High Efficiency DC-DC Converters
2
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
INPUT
VOLTAGE
36-75 Vdc
36-75 Vdc
OUTPUT VOLTAGE
1
2
3.3 V
1.8 V
5V
3.3 V
OUTPUT CURRENT (8)
1
2
8.5 A
8.5 A
7.5 A
7.5 A
OVP (1)
1
2
4.12 V
2.34 V
6.25 V
4.12 V
TYPICAL
EFFICIENCY
MODEL
NUMBER (7,9,10)
86.4% EXB50-48D3V3-1V8J
89%
EXB50-48D05-3V3J
Notes
1 Latching OVP response time is 2 ms (typ.). OVP latch is reset by toggling
the control input, or by cycling the input voltage.
2 User must provide recommended fuses in order to comply with safety
approvals.
3 Meets both level A and level B conducted emissions only with external
components connected before the input pins to the converter.
4 Maximum temperature on hotspots not to exceed 110 ºC. See Application
Note 127 on Artesyn Technologies website www.artesyn.com.
5 See the longform datasheet for derating curves.
6 For stable operation connect an external output capacitor of at least
100 µF to each output. Recommended capacity AVX TPS series
(e.g. TPSD107*010#0100) or equivalents.
7 Active low remote ON/OFF, is available. Standard product is active high.
Designate with the suffix ‘-R’ e.g. EXB50-48D05-3V3-RJ.
8 Maximum total current from the module is 15 A for EXB50-48D05-3V3J and
17 A for EXB50-48D3V3-1V8J with airflow.
9 The ‘J’ suffix indicates that these parts are Pb-free (RoHS 6/6) compliant.
TSE RoHS 5/6 (non Pb-free) compliant versions may be available on
special request, please contact your local sales representative for details.
10 NOTICE: Some models do not support all options. Please contact your
local Artesyn representative or use the on-line model number search tool at
http://www.artesyn.com/powergroup/products.htm to find a suitable
alternative.
PROTECTION
Short circuit
Overvoltage
Thermal
TELECOM SPECIFICATION
Central office interface A
Continuous
Latching
125 °C with
automatic recovery
ETS300-132-2 input voltage
and current requirements
CAUTION: Hazardous internal voltages and high temperatures.
Ensure that unit is not user accessible.
EXTERNAL OUTPUT TRIMMING
+ OUT
TRIM
- OUT
+ OUT
TRIM
TRIM
DOWN
- OUT
TRIM
TRIM
UP
Max open-frame
converter height
Ø0.040 ±0.002
(Ø1.02 ±0.05)
9 Places
Minimum clearance from
bottom of converter to
lowest component
2.280±0.02
(57.91±0.5)
Vin-
Vo2+
Vo2-
Trim2
Control
Vin+
Vo1+
Vo1-
Trim1
1.900
(48.26)
BOTTOM VIEW
All dimensions in inches (mm)
General tolerance ±0.01in (±0.25mm)
except where specified otherwise
PIN CONNECTIONS
PIN NUMBER
1
2
3
4
5
6
7
8
9
10
FUNCTION
- Vin
No Pin
Remote ON/OFF
+ Vin
Vo1 Trim
Vo1 Return
Vo1+
Vo2 Trim
Vo2 Return
Vo2+
Datasheet © Artesyn Technologies® 2005
The information and specifications contained in this datasheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising
from printing errors or inaccuracies. Specifications are subject to change without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein.
Please consult our website for the following items:  Application Note  Longform Datasheet
www.artesyn.com
File Name: exb50d.pdf Rev (02): 30 Nov 2005