English
Language : 

EXA40 Datasheet, PDF (2/4 Pages) Artesyn Technologies – 40W High Efficiency DC/DC Converters
EXA40 Series
Single output
DC/DC CONVERTERS 40W High Efficiency DC/DC Converters
2
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
INPUT SPECIFICATIONS
MINIMUM
Remote ON/OFF
ON
OFF
Remote ON/OFF source current
Active low, control to -Vin,
open collector input
Open circuit voltage
1.0V
TYPICAL
4.5V
2.5V
-70µA
MAXIMUM
5.5V
-100µA
INPUT
VOLTAGE
18-36VDC
18-36VDC
18-36VDC
18-36VDC
36-75VDC
36-75VDC
36-75VDC
36-75VDC
OUTPUT
VOLTAGE (2)
1.5 to 2.0V
2.5 to 3.0V
3.0 to 3.6V
4.5 to 5.5V
1.5 to 2.0V
2.5 to 3.0V
3.0 to 3.6V
4.5 to 5.5V
NOMINAL
OUTPUT VOLTAGE
1.8V
2.75A
3.3V
5.0V
1.8V
2.75V
3.3V
5.0V
OUTPUT
CURRENT (MAX.)
8.0A
8.0A
8.0A
8.0A
8.0A
8.0A
8.0A
8.0A
TYPICAL
EFFICIENCY
84%
87%
88%
90%
84%
86%
88%
91%
MODEL
NUMBER (1)
EXA40-24S1V8
EXA40-24S2V75
EXA40-24S3V3
EXA40-24S05
EXA40-48S1V8
EXA40-48S2V75
EXA40-48S3V3
EXA40-48S05
EMC CHARACTERISTICS (Continued)
ETS 300 386-1 table 5
Conducted emissions
(See Design Note 101)
Radiated emissions
ESD air
ESD contact
Surge (500V)
Fast transients
Radiated immunity
Conducted immunity
EN55022, internal filter
and 4.7µF film cap
EN55022, external filter,
EN55022 (See Design Note)
EN61000-4-2, level 3
EN61000-4-2, level 4
EN61000-4-5, level 3,4
EN61000-4-4, level 3,4
EN61000-4-3, level 3
EN61000-4-6, level 3
Level A
Level B
Level B
GENERAL SPECIFICATIONS
Efficiency
See table
Basic insulation
Input/output
1500VDC
Input fuse 24V
Input fuse 48V
(See Note 8)
3.5A slow blow
2.0A slow blow
Switching frequency
Fixed
300kHz
Approvals and
standards
(See Notes 1, 7, 8, 9)
(See Notes 1, 7, 8, 9)
EN60950
Bi-national UL1950
CSA C22.2 No. 234/950
Weight
25g (0.88 oz)
MTBF, See Design Note MIL-HDBK-217
250,000 hours
Notes
1 True latching OVP is available as an option. Please add the suffix ‘-V’ to the
model number, e.g. EXA40-24S1V8-V. Additional alphanumeric suffixes
maybe added to indicate minor modifications not affecting the safety
approvals.
2 Guaranteed minimum output voltage range.
3 Latching OVP response time is 1ms (typical). OVP latch is reset by toggling
remote ON/OFF or by recycling the input voltage.
4 Figures are percentage of minimum input voltage.
5 Rshort ≤20mΩ.
6 TVS spec : 6V8 @ 10mA, 10V5 @ 57A
4V1 @ 1mA, 7V3 @ 50A
7 Maximum continuous output power.
40 Watts for S05 models
26.4 Watts for S3V3 models
22 Watts for S2V75 models
14.4 Watts for S1V8 models.
8 User must provide recommended fuses in order to comply with safety
approvals.
9 Maximum temperature on components Q100, Q102 and Q103 not to
exceed 120°C. See Application Note for details.
DERATING CURVE
Output Power (%)
100%
75%
EXA40-24S05
All other Models
ENVIRONMENTAL SPECIFICATIONS
Thermal performance
Operating ambient
temperature
Non-operating
-40°C to +70°C,
See curves
-55°C to +105°C
Over temperature
shutdown
Loss of Function
Self-Recovery (LFS)
75°C to +85°C
ETS 300 019-2-3
Classes T3.1 to T3.5
Air temperature
Low: IEC 68-2-1
High: IEC 68-2-2
Change: IEC 68-2-1
-40°C
+70°C
-40°C to +70°C
Relative humidity
IEC 68-2-56
IEC 68-2-30
10% to 100% RH
Condensation
Vibration, Class 3M5
IEC68-2-6
MIL-STD-202F
2 to 9 Hz, 3mm disp.
9 to 200Hz 1g
Method 204 cond. A
Shock, Class 3M5
IEC-68-2-29
MIL-STD-202F Method 213B cond. A
50%
25%
27.5%
0%
-40°C -30°C-20°C -10°C 0°C 10°C 20°C 30°C 40°C 50°C 60°C 70°C 80°C 90°C 100°C
AMBIENT TEMPERATURE (°C)
Figure 1: Natural Convection (0.1m/s) Typical derating, See Application Note.
CAUTION: Hazardous internal voltages and high temperatures.
Ensure that unit is not user accessible.
Please consult our website for the following items: Application Note Shortform Data Sheet
www.artesyn.com
File Name: LF_EXA40.PDF Rev: 15 Jan 2002