English
Language : 

DS450HE-3 Datasheet, PDF (2/4 Pages) Artesyn Technologies – Embedded Power for Business-Critical Continuity
Embedded Power for
Business-Critical Continuity
Logic Control
PS Inhibit:
PS_Status:
AC_Pfail:
Fan_Fault:
Tach_1:
Rev. 03.02.10_70
DS450HE-3/DS550HE-3
2 of 4
When supply is inserted into the system the pin is pulled LOW and power supply is ON after all other pins are seated
I2C port P6. When the power supply is on and running normal P6 is low. When the power supply is off, either due to
-PS_ON, PS_KILL, or a fault, then P6 is high.
I2C port P7. P7 is high except when the power supply turns the main outputs, not +3.3 Vsb, off due to an AC failure
(AC missing or too low for power supply operation). If the supply is turned off due to -PS_ON, PS_KILL, or a fault,
then P7 remains high.
The PSU will provides an open collector Tach 1 output.
This signal is generated from the fan. The signal should generate 2 pulses per revolution. The logic in the
system will be operating at 3.3 V.
Environmental Specifications
Operating temperature:
-10 °C to 50 °C
Storage temperature:
Altitude, operating:
-40 °C to +70 °C
10,000 ft.
Electromagnetic
-EN61000-3-2, -3-3
susceptibility / Input transients: -EN61000-4-2, 4.3, 4-4, -4-5, 4-11 Level
-EN55024:1998
RoHS & lead-free compliant (no tantalum caps)
Humidity:
20 to 90% RH, non-condensing
Shock and vibration specificatons complies with Emerson Network Power Std. Specification, Q3205
MTBF (Demonstrated):
400K Hrs at full load, 40 °C
Ordering Information
Output
Nominal Output Set Point Total Minimum Maximum
Voltage Set Point Tolerance Regulation Current
Current
DS450HE-3
12.0 Vdc
3.3 Vsb
± 0.2% +5 / -3%
0A
± 1% +5 / -4%
0A
37.0 A
3.0 A
DS550HE-3
12.0 Vdc
3.3 Vsb
± 0.2% +5 / -3%
0A
± 1% +5 / -4%
0A
45.0 A
3.0 A
*Overcurrent latches off if overcurrent lasts over 1 second, otherwise it is auto recovery.
*For 5 Vsb, consult marketing.
Output Ripple
P/P
120 mV
60 mV
120 mV
60 mV
Overcurrent
39.5 A - 44.4 A
4.9 A Avg, 7 A max
48.0 A - 54.0 A
4.9 A Avg, 7 A max
95
90
85
80
75
110 V EFFICIENCY %
220 V EFFICIENCY %
70
65
60
55
50
10
20
30
50
75
100
LOAD %