English
Language : 

DS450DC-3 Datasheet, PDF (2/4 Pages) Emerson Network Power – Distributed Power System
DS450-3/DS550-3 Data Sheet
Logic Control
PS_ON /L(Power supply enable) The power supply output will be enabled when this signal is pulled low (< 0.8 V).
HIGH = Output V1 OFF
LOW = Output V1 ON
VIN_GOOD/H (Input OK)
Active High signal asserted when the input voltage rises above the min input voltage specified.
This signal is internally pulled up through 4.7 K ohms to the 3.3 V housekeeping voltage.
POK/H (Output OK)
TACH_1
PS_KILL
Active High signal asserted when the output is within regulation. This signal is internally pulled up through 1.0 K
ohms to the 3.3 V housekeeping voltage.
This open collector signal generates two pulses per each fan revolution. This signal is eternally pulled up to the
housekeeping voltage.
This signal will cause the output to shut down when drive high (> 24 V) or left floating. The PS_KILL will cause the
output to latch off and requires recycle of PS_ON or DC input to reset.
Environmental Specifications
Operating temperature
+10 °C to +45 °C, able to start-up at -10 °C
Storage temperature
-40 °C to +70 °C
Altitude, operating
10,000 ft.
Electromagnetic susceptibility/Input transients
- EN61000-3-2, -3-3
- EN61000-4-2, 4.3, 4-4, -4-5, 4-11
- EN55024:1998
RoHS & lead-free compliant (no tantalum caps.)
Humidity
20 to 90% RH, non-condensing
Shock and vibration specificatons complies with Astec Std. Specifications.
MTBF (calculated)
500k hours at full load, 25 °C
Ordering Information
Output
Nominal Output
Voltage Set Point
DS450DC-3
12.0 Vdc
3.3 Vsb
DS450DC-3-002
12.0 Vdc
3.3 Vsb
DS550DC-3
12.0 Vdc
3.3 Vsb
DS550DC-3-003
12.0 Vdc
3.3 Vsb
Set Point
Tolerance
± 0.2%
± 1%
± 0.2%
± 1%
± 0.2%
± 1%
± 0.2%
± 1%
Total
Regulation
+5/-3%
+5/-4%
+5/-3%
+5/-4%
+5/-3%
+5/-4%
+5/-3%
+5/-4%
Minimum
Current
0A
0A
0A
0A
0A
0A
0A
0A
Maximum
Current
37.0 A
3.0 A
37.0 A
3.0 A
45.0 A
3.0 A
45.0 A
3.0 A
Output Ripple
P/P
Over Current
Options
120 mV
60 mV
39.5 - 44.4%
4.9 A Avg, 7 A max
Standard
120 mV
60 mV
39.5 - 44.4%
4.9 A Avg, 7 A max
Reverse Air
120 mV
60 mV
48.0A - 54.0A
4.9 A Avg, 7 A max
Standard
120 mV
60 mV
48.0A - 54.0A
4.9 A Avg, 7 A max
Reverse Air
*Over current latches off if overcurrent lasts over 1 second, otherwise it is auto recovery.
*For 5 Vsb, please contact marketing department.