English
Language : 

DS450-3 Datasheet, PDF (2/4 Pages) Astec America, Inc – 450-550 Watts 12V DS450-3/DS550-3 Distributed Power System
DS450-3/DS550-3 Data Sheet
Logic Control
PS Inhibit
PS_Status
AC_Pfail
Fan_Fault
Tach_1
When supply is inserted into the system the pin is pulled LOW and power supply is ON after all other pins are seated
I2C port P6. When the power supply is on and running normal P6 is low. When the power supply is off, either due
to -PS_ON, PS_KILL, or a fault, then P6 is high.
I2C port P7. P7 is high except when the power supply turns the main outputs, not +3.3 Vsb, off due to an AC failure
(AC missing or too low for power supply operation). If the supply is turned off due to -PS_ON, PS_KILL, or a fault,
then P7 remains high.
The PSU will provides an open collector Tach 1 output.
This signal is generated from the fan. The signal should generate 2 pulses per revolution. The logic in the system
will be operating at 3.3 V.
Environmental Specifications
Operating temperature
-10 °C to 50 °C
Storage temperature
-40 °C to +70 °C
Altitude, operating
10,000 ft.
Electromagnetic susceptibility/Input transients
-EN61000-3-2, -3-3
-EN61000-4-2, 4.3, 4-4, -4-5, 4-11
-EN55024:1998
RoHS & lead-free compliant (no tantalum caps)
Humidity
20 to 90% RH, non-condensing
Shock and vibration specificatons complies with Artesyn Embedded Technologies Std. Specification.
MTBF (Demonstrated)
400 K Hrs at full load, 40 °C
Ordering Information
Output
Nominal Output
Voltage Set Point
DS450-3
12.0 Vdc
3.3 Vsb
DS450-3-002
12.0 Vdc
3.3 Vsb
DS550-3
12.0 Vdc
3.3 Vsb
Set Point
Tolerance
± 0.2%
± 1%
± 0.2%
± 1%
± 0.2%
± 1%
Total
Regulation
+5/-3%
+5/-4%
+5/-3%
+5/-4%
+5/-3%
+5/-4%
Minimum
Current
0A
0A
0A
0A
0A
0A
Maximum
Current
37.0 A
3.0 A
37.0 A
3.0 A
45.0 A
3.0 A
Output Ripple
P/P
Overcurrent
Options
120 mV
60 mV
39.5 A - 44.4 A
4.9 A Avg, 7 A max
Standard
120 mV
60 mV
39.5 A - 44.4 A
4.9 A Avg, 7 A max
Reverse Air
120 mV
60 mV
48.0 A - 54.0 A
4.9 A Avg, 7 A max
Standard
*Overcurrent latches off if overcurrent lasts over 1 second, otherwise it is auto recovery.
*For 5 Vsb, please contact marketing department.